33D4047
ELECTRICAL WIRING (MILLI-VOLT)
The milli-volt valve is a self-powered combination gas control THAT DOES NOT REQUIRE 110 VAC TO 
OPERATE.
CONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT
1.  Use 18 awg, two-wire cable, 20 feet maximum length.
2.  At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to TP/TH 
and one wire to TH. The color of the wires does not matter.
Optional Wall
Switch, Thermostat,
or Remote Receiver
Switch
On/Off
Switch
On/Off
Switch
Wall
Switch
ODS 
Pilot
Millivolt 
Valve
Red
 TH = 3
TP = 1
TP/TH = 2
Figure 31 - Wiring Diagram
Red
ODS 
Pilot
Spade 
Terminal
CAUTION
Label all wires prior to 
disconnection when 
servicing controls. 
Wiring errors can 
cause improper and 
dangerous operation. 
Verify proper operation 
after servicing.