The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two 
(2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws 
to attach fireplace to framing. The side brackets are adjustable from 1/2" to 5/8" to accommodate 
different thickness of noncombustible material. 
SecuRe FIRepLAce to FLooR oR FRAMING 
Note: Do not allow combustibles (drywall) to touch top and side edges of black-painted metal 
face of fireplace. only use noncombustibles. A 4" wide or more cement board may touch the 
top and side edges of black-painted metal face of fireplace.
Do not allow any combustible to overlap the black-painted face of fireplace. 
OFF
FP2712
secure fireplaces
Figure 6 - 
Securing Fireplace to Floor and Framing Studs 
Framing
Framing 
Adjustable 
Bracket 
Adjustable 
Bracket 
Screws
Screws
Screws 
FP2712
FINIShING MAteRIAL
Note: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to 
final finishing to avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating 
of Zero) may be used to cover the black surface of the appliance. A 300
°
F minimum adhesive may 
be used to attach facing materials to the black surface. If joints between the finished wall and the 
fireplace  surround  are  sealed,  a  300
°
F  minimum  sealant  material  (General  Electric  RTV103  or 
equivalent) must be used.
W
ARNING
Never  obstruct  or  modify  the  air  inlet  or 
outlet  grills  (louvers).  this  may  create  a 
fire hazard.