tRouBLeShootING
W
ARNING
turn  appliance  oFF  and  allow  to  cool  before 
servicing.
only  qualified  service  person  should  service 
and repair the heater.
oBSeRVeD pRoBLeM
Spark  ignitor  will  not  light  the 
pilot after repeated pressing of 
spark ignitor. 
Pilot will not stay lit. 
Burner will not light when valve 
and burner switch are both on.
Glass fogs up
Blue flames
Sooting 
poSSIBLe cAuSe
1.  Battery needs replacing 
2.  Defective ignitor
3.  Misaligned spark electrode 
4.  Bad wire.
1.  Defective thermocouple. 
Loose thermocouple
2.   Air in gas line
3.  No gas
1.  Defective switch
2.  Defective thermopile
3.  Thermostat set too low/defective 
1.  Normal condition 
1.  Normal during start up 
1.  Flame impingement 
ReMeDy
1.  Replace battery
2.  Check connections to ignitor. Replace 
ignitor if ignitor connections are good, 
but there is no spark.
3.  Check for spark arcing from the elec-
trode to pilot. Adjust and retighten. 
4.  Replace with new wire. 
1.  A.  Check  for  proper  connection  of 
thermocouple to rear of valve. 
  B. Check thermocouple output. 
2.  Bleed line. Contact dealer 
3.  Check shutoff valve and gas supply 
(LPG tank)
1.  Check  switch  connections.  Jump 
wires at switch. 
2.  A. Check thermopile output. 
  B. Check connections to valve. Con-
tact dealer. 
3.  Turn  up  thermostat  to  start  unit. 
Check thermostat connections. 
1.  Allow appliance to warm up. Glass 
will clear. Additives in the gas may 
dirty glass. Clean glass when cool. 
1.  Flames  will  yellow  as  appliance 
heats up. Adjust rock wool placement 
per instructions.
1.  Check log position. Open shutters to 
increase primary air. 
Note: All troubleshooting items are listed in 