Monessen Hearth KHLDV400 User Manual

Page of 64
28
73D0024
KHLDV Series Gas Fireplace
Continued on next page 
approVeD LeaK teStInG MetHoD 
You may check for gas leaks with the following methods 
only:
  •  Soap and water solution
  •  An approved leak testing spray
  •  Electronic sniffer
If  using  a  soap  and  water 
solution  to  test  for  leaks, 
Do not spray solution onto 
control body. 
w
arn
In
G
NOTE:  Remove  any  excessive  pipe 
compound  from  the  connections. 
Excessive pipe compound can set off 
electronic sniffers. 
the control has an interlock device that does not allow the lighting of the fireplace 
up to the moment the safety device of the flame has not  interrupted the gas flow. 
after that period of time (when the magnet is closed), it is possible to start the 
lighting operation. 
the gas control knob is designed to be operated by hand. Do not use any tools 
during this operation. Damaged knobs may result in serious injury. 
w
arn
In
G
1.  Depress and turn knob counterclockwise 
 
to pilot position. 
2.  Depress fully and hold pilot gas knob. Depress 
piezo igniter as many times as needed to ignite pilot.  
Keep knob fully depressed for a few seconds. 
Release  and  check  that  pilot  continues  to 
burn. 
If the pilot does not stay lit, repeat steps 1 and 2. 
LIGHtInG pILot
Figure 39 - 
Pilot Position 
Check for gas leaks in each of the following locations:
  •  Pipe from the gas supply line connection to the gas valve
  •  Burner connections  
•  Field made joints / gas shutoff valve 
  •  Pilot  
•  Factory made joints
  •  Each joint or connection 
•  All joints on valve and control body
never check for gas leak with open flame!
D
an
G
er
LIGHtInG pILot For tHe FIrSt tIMe
MILLIVoLt - operatInG InStructIonS 
PILOT
OF
F
PI
LO
T
ON
FP1935
control knob pilot