Monessen Hearth KHLDV400 User Manual

Page of 64
73D0024
31
KHLDV Series Gas Fireplace
eLectrIcaL InStaLLatIon
junctIon Box wIrInG
1.  This  should  be  done  before  framing  the fireplace.  Wire the  receptacle  into  an  electrical  circuit. 
Wire with minimum 60° C wire in accordance with prevailing 
codes.
2.  Remove  the  external  junction  box  cover  by  removing  the 
screw from the side of the outside firebox wall. Junction box 
was installed at the factory.
3.  The junction box cover has a factory installed “romex” style 
strain relief connector. After connecting the wires, route the 
wire leads through this connector. Refer to the wiring dia-
gram in Figure 45.
Figure 45 - 
Junction Box Wiring Diagram
FP1912
Junction box wiring
8/08
Junction Box
Factory Supplied
Not Supplied
120V AC
60Hz
coMManD center waLL InStaLLatIon
The command center may be mounted on the wall with 
the  use  of  the  SCSWEK  Kit  (15ft.  cable,  junction  box, 
wall cover).
Mount the junction box provided at the desired location 
on the wall. Do not extend beyond the 15 ft. wire cable 
provided. If a longer distance is required, the 15 ft. may be 
extended up to 30 ft. maximum by using two (2) SCSWEK 
cables plugged together.
Route  the  wire  from  junction  box  to  lower  control  area 
at  bottom  of  fireplace.  Unplug  the  12"  cable  from  the 
command center. Attach the connector to the pins from 
wire by pushing in to connector making sure to follow the 
color code on connector. Plug the 15 ft. extension cable 
into the 2 ft. cable. Remove command center from the 
fireplace and plug the other end of the extension cable 
into the command center. Snap on wall cover provided 
and screw to junction box.
waLL SwItcH InStaLLatIon
The  wall  switch  wire  connection  is  located  off  the  2  ft. 
wire harness from the control box to the command center. 
Figure 46. The connection is labeled “Wall Switch”. Unplug 
the male and female connectors and connect the two (2) 
low voltage wires provided. Run wire to desired location 
on wall. Up to 50 ft. of 18 ga. wire may be used if neces-
sary. Attach wires to wall switch. Mount the wall switch in 
to junction box and screw on cover.
w
arn
In
G
Do  not  connect  wall  switch  to  110  V 
circuit.