PRE-INSTALLATION INFORMATION
INSTALLING ABOVE 2000 FEET
•  In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations.
•  In Canada, these appliances are certified for altitudes of 0 – 2000 ft, and must be de-rated by 10 percent for installations 
between 2000 and 4,500 ft. (derate an additional 4% for every 1,000 ft. above 4,500 ft. elevations). 
The IDV490NVC, IDV490PVC, IDV380NVC, and 380IDVPVC are equipped with a variable output gas control.
ORIFICE SIZES, PRESSURES AND BTUs
NATURAL GAS 
 
PROPANE GAS
Manifold Press: (W.C.) 
3.5" 
Manifold Press: (W.C.) 
10" 
Maximum Supply Pressure  10.5" 
Maximum Supply Pressure 
13"   
Minimum Supply Pressure 
 4.5" 
Minimum Supply Pressure 
11" 
NOTE:   IDV490NVC, IDV490PVC, IDV380NVC, and IDV380PVCinserts work without any electrical supply.  
Blower must be attached to 110/120 VAC.
INSTALLATION PLANNING 
Plan for the installation of your insert. This includes determining the size of fireplace in which unit is to be installed, length of 
venting to be used, and finishing details, and whether any optional accessories (i.e. wall switch, or remote control) are desired. 
Consult your local building code agency to ensure compliance with local codes, including permits and inspections.
 
Model Number 
IDV490NVC
IDV490PVC
IDV380NVC
IDV380PVC
    
NATURAL 
PROPANE 
NATURAL 
PROPANE
  Max. Btu/hr Input 
40,000 
37,500 
30,500 
28,000
  Min. Btu/hr Input 
26,500 
29,000 
20,500 
22,000
  Orifice sizes (as shipped) 
#30 
#50 
#35 
#53