Monessen Hearth ILDV20PV User Manual

Page of 40
6
83D0511
ILDV20/ILDV30 Fireplace Insert
PRe-iNStALLAtiON iNFORMAtiON
ORiFice SiZeS, PReSSuReS AND Btus
NAtuRAL GAS 
 
PROPANe GAS
Manifold Press: (w.c.) 
3.5" 
Manifold Press: (w.c.) 
10" 
Maximum Supply Pressure 
10.5" 
Maximum Supply Pressure 
13"   
Minimum Supply Pressure 
 4.5" 
Minimum Supply Pressure 
11" 
BeFORe yOu StARt
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all con-
tents for shipping damage and immediately inform your dealer if any damage is found. Do 
not install any unit with damaged, incomplete, or substitute parts. Check your packing list to 
verify that all listed parts have been received.
NOte: The ILDV Series fireplace inserts work without any electrical 
supply. The blower must be attached to 110/10V AC.
 
Model Number 
iLDV20NV 
iLDV20PV 
iLDV30NV 
iLDV30PV
 
Gas Type 
Natural 
Propane 
Natural 
Propane
 
Max. BTU/hr Input 
0,000 
0,000 
30,000 
30,000
 
Min. BTU/hr Input 
13,000 
16,000 
0,500 
3,000
 
Orifice Size (as shipped) 
#44 
1.35 mm 
#37 
#51
hiGh eLeVAtiONS
Input ratings are shown in BTU per hour and are certified without deration for 
elevations up to 4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, installation must be in accor-
dance with the current ANSI Z3.1/NFPA 54 and/or local codes having jurisdic-
tion.
In Canada, please consult provincial and/or local authorities having jurisdiction 
for installation at elevations above 4,500 feet (1,370 m).