Monessen Hearth ILDV20PV User Manual

Page of 40
83D0511
ILDV20/ILDV30 Fireplace Insert
9
cLeARANceS
iNSeRt cLeARANceS
No combustibles (ie: drapes, doors) may be within, or swing within 36" of the front of the insert.
MANteL cLeARANceS 
NOte: the combustible area above the facing must not protrude more than 
3
/4" from the 
facing. if it does, it is considered a mantel and must meet the mantel requirements listed 
in this manual.
heARth RequiReMeNtS
The insert must be installed on a noncombustible hearth extending a minimum of 1" from the 
fireplace opening (local codes may require a larger hearth). The hearth must also extend to both 
sides of the face (Refer to the table on Page 7).
12” (305 mm)
Maximum Depth
12”
(305 mm)
Side Wall
Combustible Mantel
Top Facing
Side Facing
3/4” (19 mm)
Maximum Depth 
Combustible Facing
42” (1067 mm)
Minimum
10” (254 mm)
Minimum
12” (305 mm)
Minimum
FP1947
insert clearances
9/08
9”
(228 mm)
FP1947
Figure 3
Mantel Clearances
NOte: Side clearance to com-
bustibles is 10" (54 mm) from 
opening whether it is side wall 
or mantel legs.