LX Series Direct Vent Gas Fireplace
BeLoW GRADe INStALLAtIoNS
When it is not possible to meet the required vent terminal 
clearances of 12" above grade level, a snorkel kit is recom-
mended. It allows installation depth down to 7" (178 mm) 
below grade level. The 7" (178 mm) is measured from the 
center of the horizontal vent pipe as it penetrates through 
the wall.
ensure that sidewall venting clearances are observed. 
If venting system is installed below ground, we recom-
mend a window well with adequate and proper drainage 
to be installed around the termination area.
If installing a snorkel, a minimum 24" vertical rise is neces-
sary. The maximum horizontal run with the 24” (610 mm) 
vertical pipe is 36" (914 mm). This measurement is taken 
from the collar of the fireplace (or transition elbow) to the 
face of the exterior wall. See the Sidewall Venting Graph 
for extended horizontal run if the vertical exceeds 24".
1.  Establish vent hole through the wall. Page 17, Figure 
15
2.  Remove soil to a depth of approximately 16" (406 mm) 
below base of snorkel. Install drain pipe. Install window 
well  (not  supplied).  Refill  hole  with  12"  (305  mm)  of 
coarse gravel leaving a clearance of approximately 4" 
below snorkel. Figure 25
3.  Install vent system.
4.  Ensure a watertight seal is made around the vent pipe 
coming through the wall.
5.  Apply  high  temperature  sealant  caulking  (supplied) 
around the 4" and 7" snorkel collars.
6.  Slide the snorkel into the vent pipes and secure to the 
wall.
7.  Level the soil so as to maintain a 4" clearance below 
snorkel. Figure 25
VeNtING INStALLAtIoN
FP1965
below grade install
24”
Minimum
Figure 25 -  
Below Grade Installation
Screws
Minimum 
4" Clearance
Ground
Window 
Well 
Gravel 
Drain 
Foundation Wall 
Firestop 
FP1965
FP1966
snorkel
Figure 26 - 
Snorkel Installation, Recessed Foundation
Foundation
Recess 
Watertight Seal 
Around Pipe 
Sheet Metal 
Screws 
Snorkel
Wall Screws
FP1966
If  the  foundation  is  recessed,  use  recess  brackets  (not 
supplied) for securing lower portion of the snorkel. Fasten 
brackets to wall first, then secure to snorkel with self drill-
ing #8 x 1/2 sheet metal screws. It will be necessary to 
extend vent pipes out as far as the protruding wall face. 
Figure 26
W
ARNING
  Do not back fill around snorkel.
  A  clearance  of  at  least  4"  must  be 
maintained between the snorkel and 
the soil.
VeRtIcAL thRouGh-the-RooF AppLIcA-
tIoNS 
This Gas Fireplace has been approved for,
   Vertical installations up to 40' (12 m) in height. Up to 
a 10' (3 m) horizontal vent run can be installed within 
the vent system using a maximum of two 90° elbows. 
Figure 27
  Install restrictor disk on vertical runs of 10' or more.
   Up to two 45° elbows may be used within the horizontal 
run. For each 45° elbow used on the horizontal plane, 
the maximum horizontal length must be reduced by 18" 
(450 mm). 
example: Maximum horizontal length 
   
No elbows  =  10’ (3 m)
  1 x 45° elbows  =  8.5’ (2.6 m)
  2 x 45° elbows  =  7’ (2.1 m)
   A minimum of an 8' (2.5 m) vertical rise is required.
   Two sets of 45°elbows offsets may be used within the 
vertical sections. From 0 to a maximum of 8' (2.5 m) of 
vent pipe can be used between elbows. Figure 28
   The maximum angular variation allowed in the system 
is 270°. Figure 28
  See termination height on Page 22.