pRoDuct FeAtuReS  
  This  appliance  has  been  certified  for  use  with 
either natural or propane gas. See appropriate data 
plates.
  This appliance is not for use with solid fuels.
  The appliance is approved for bedroom or bedsitting 
room installations.
  The appliance must be installed in accordance with 
local codes if any. If none exist use the current instal-
lation code. ANSI Z223.1/NFPA 54 in the USA, CSA 
B149 in Canada.
  This appliance is mobile home approved.
  The appliance must be properly connected to a vent-
ing system.
 
pRoDuct SpecIFIcAtIoNS
OFF
FP2710
LX controls
Off/Pilot/On
Knob 
Optional Remote 
Receiver 
Figure 1 - 
LXDV Fireplace  Controls
Hi/Lo Knob 
Blower Control 
On/Off/
RS Switch 
FP2710
GAS pReSSuReS
hIGh eLeVAtIoNS
Input ratings are shown in BTU per hour and are certi-
fied  without  deration  for  elevations  up  to  4,500  feet 
(1,370 m) above sea level.
For  elevations  above  4,500  feet  (1,370  m)  in  USA, 
installations  must  be  in  accordance  with  the  current 
ANSI  Z223.1/NFPA  54  and/or  local  codes  having 
jurisdiction.
In  Canada,  please  consult  provincial  and/or  local 
authorities having jurisdiction for installations at eleva-
tions above 4,500 feet (1,370 m).
   
Natural 
Propane (LP)
  Inlet Minimum 
4.5” w.c. 
11.0” w.c.
  Inlet Maximum 
10.5” w.c. 
13.0” w.c.
  Manifold Pressure 
3.5” w.c. 
10.0” w.c.
    
 
Max.Input 
Min. Input 
orifice Size 
  Model 
Fuel 
Btu/h 
Btu/h 
Front  Rear
  LX32NV 
Nat. 
36,000 
26,000 
#46 
#43
  LX32PV 
LP 
36,000 
22,000 
3/64" 
#55
  LX36NV 
Nat. 
44,000 
30,000 
#41 
#38
  LX36PV 
LP 
44,000 
32,000 
#55 
#53
GAS SpecIFIcAtIoNS & oRIFIce SIZe