Monessen Hearth KHLDV SERIES User Manual

Page of 52
10 
73D0024
FIREPLACE
WALL
COMBUSTIBLE
MATERIAL
AREA
6"
5"
3"
2.5"
4.5"
45°
3.5"
3.5"
1"
1.5"
1.5"
Follow these instructions carefully to ensure safe installation. Failure to follow 
in struc tions exactly can create a fi re hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other 
than wood fl ooring. If installed on carpet or vinyl fl ooring, the appliance shall be installed 
on a metal, wood or noncombustible material panel ex tend ing full width and depth of 
the appliance.
W
ARNING
CLEARANCES
CLEARANCES TO COMBUSTIBLES 
MANTEL CLEARANCES 
NOTE: The combustible area above the facing must not protrude more than 
3
/
4
" from the facing. If it does, 
it is considered a mantel and must meet the mantel requirements listed in this manual. 
Figure 5 - Clearances from the mantel, 
ceiling, and side wall. 
Figure 5a - Mantel clearances.