62D4036
CHECKING GAS PRESSURE
1.   Check gas type. The gas supply must be the same as 
stated on the applianceʼs rating decal. If the gas supply 
is different from the fireplace, STOP! Do not install 
the appliance. Contact your dealer immediately.
2.   To ease installation, a 30" (mm) flex line with manual 
shut-off valve has been provided with on this appliance. 
Install and attach 
1
/
2
" gas line onto shut-off valve. 
3.   After completing gas line connection, purge air from 
gas line and test all gas joints from the gas meter to 
the fireplace for leaks. Use a solution of 50/50 water 
and soap or a gas sniffer. 
4.   To adjust flame height, turn HI/LO knob to HI to get 
maximum pressure to burner. Turn HI/LO knob to LO 
to get minimum pressure. 
5.   To check gas pressures at valve, turn captured screw 
counter clockwise 2 or 3 turns and then place tubing to 
pressure gauge over test point. Turn unit to high.  See 
Figure 18. After taking pressure reading, be sure and 
turn captured screw clockwise firmly to reseal. Do not 
over torque. Check test points for gas leaks.