OUTSIDE COMBUSTION AIR PRECAUTIONS AND RECOMMENDATIONS 
Note: The use of outside air for combustion 
is  optional  unless  required  by  building 
codes.  It  is  only  necessary  to  supply 
outside  combustion  air  to  one  side  of 
fireplace.  Use  model  OAC4  combustion 
air kit (see page 17). 
1.  Avoid  extremely  long  runs  and  numerous 
turns in duct leading from fireplace to combus-
tion air assembly. These conditions increase 
the resistance to free flow of air through duct. 
See Figures 11 and 12.
2.  Locate combustion air assembly at an exterior 
location. Make sure the location cannot be 
accidentally blocked. Locate assembly above 
snow  line  to  prevent  snow  from  blocking 
assembly.
3.  Never mount combustion air inlet assembly 
in  garage  or  storage  area  where  combus-
tible fumes (gasoline) might be drawn into 
fireplace.
4.  Combustion air may be drawn from crawl 
space  under  house  when  adequate  supply 
of air is provided by open ventilation.  See 
Figure 11.
Note: Never take combustion air from attic 
space or garage space. 
Note: Install outside combustion air ONLY 
ON LEFT-HAND SIDE of fireplace. 
Figure 11 - Installing Unit Above Basement or Crawl Space 
Figure 12 - Installing Unit on Concrete Slab with Optional 
Outside Air Runs 
Duct 
Extended to 
Miss Joist 
To Outside Wall 
Inlet Grill in Soffit 
(Overhag)