Monessen Hearth SBV400 User Manual

Page of 42
28
 
62D4036
Figure 29 - Pilot Flame 
Thermopile 
Thermocouple 
Turn  off  gas  before  servicing  fireplace.  It  is  recommended  that  a  qualified  service 
technician perform these check-ups at the beginning of each heating season
W
ARNING
BURNER FLAME
The flames from the burner should be visually checked 
as soon as the heater is installed and periodically during 
normal operation. In normal operation, at full rate, and 
after operating for about 15 to 30 minutes, the flame 
should be yellow and slightly taller than the rear log. 
See Figure 30.
NOTE:  The  type  of  installation,  vent  system 
configuration, and wind effects may cause the 
flame patterns to vary.
Figure 30 - Burner Flame Appearance 
CLEANING AND MAINTENANCE 
BURNER, PILOT AND CONTROL COMPARTMENT
Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a 
year.  Make sure the burner porting, pilot air opening and burner air opening are free of obstructions at all times.
PILOT FLAME
The flames from the pilot should be visually checked as soon as the heater 
is installed and periodically during normal operation. The pilot flame must 
always be present when the fireplace is in operation. See Figure 29. The pilot 
flame has three distinct flames, one engulfing the thermopile, one engulfing the 
thermocouple, and the other reaching to the main burner.
.              
BURNER
Inspect area around the injector. Remove any lint or foreign material with a 
brush or vacuum.