Designer Series Gas Fireplaces
NoTE REGaRdING vENTEd PRoduCTS
This product must be installed by a licensed plumber or gas fitter 
when installed within the Commonwealth of Massachusetts.
Any  residence  with  a  direct  vent  product  must  have  a  CO 
detector installed in the residence.
Installation  of  the  fireplace  or  vented  gas  log  in  the  State  of 
Massachusetts requires the damper to be permanently removed 
or welded in the fully open position.
In addition, a naturally vented gas log may not be installed in a 
bedroom or bathroom in the State of Massachusetts.
Flex line installation must not exceed 36 inches and must have 
a T shutoff valve. 
NoTE REGaRdING vENT FREE PRoduCTS
This product must be installed by a licensed plumber or gas fitter 
when installed within the Commonwealth of Massachusetts.
In  addition,  vent  free  products  may  not  be  installed  in  a 
bedroom or bathroom regardless of size or type in the State of 
Massachusetts.
Flex line installation must not exceed 36 inches and must have 
a T shutoff valve.
CaRBoN MoNoxIdE dETECToR REquIREMENTS
(2) Revise  10.8.3  by  adding  the  following  additional 
requirements:
(a)  
For  all  side  wall  horizontally  vented  gas  fueled 
equipment installed in every dwelling, building or structure used 
in  whole  or  in  part  for  residential  purposes,  including  those 
owned or operated by the Commonwealth and where the side 
wall exhaust vent termination is less than seven (7) feet above 
finished  grade  in  the  area  of  the  venting,  including  but  not 
limited to decks and porches, the following requirements shall 
be satisfied:
1.  Installation  of  carbon  monoxide  detectors.  At  the  time 
of  installation  of  the  side  wall  horizontal  vented  gas  fueled 
equipment,  the  installing  plumber  or  gas  fitter  shall  observe 
that a hard wired carbon monoxide detector with an alarm and 
battery  back-up  is  installed  on  the  floor  level  where  the  gas 
equipment is to be installed. In addition, the installing plumber 
or gas fitter shall observe that a battery operated or hard wired 
carbon  monoxide  detector  with  an  alarm  is  installed  on  each 
additional level of the dwelling, building or structure served by 
the side wall horizontal vented gas fueled equipment. It shall be 
the responsibility of the property owner to secure the services of 
qualified licensed professionals for the installation of hard wired 
carbon monoxide detectors
 
a.  In the event that the side wall horizontally vented gas 
fueled equipment is installed in a crawl space or an attic, the 
hard  wired  carbon  monoxide  detector  with  alarm  and  battery 
back-up may be installed on the next adjacent floor level.
 
b.  In the event that the requirements of this subdivision 
can  not  be  met  at  the  time  of  completion  of  installation,  the 
owner shall have a period of thirty (30) days to comply with the 
above requirements; provided, however, that during said thirty 
(30) day period, a battery operated carbon monoxide detector 
with an alarm shall be installed.
Massachusetts Residents only — Please read and follow these special requirements
2.  approved  Carbon  Monoxide  detectors.  Each  carbon 
monoxide detector as required in accordance with the above 
provisions shall comply with NFPA 720 and be ANSI/UL 2034 
listed and IAS certified.
3.  Signage.  A  metal  or  plastic  identification  plate  shall  be 
permanently  mounted  to  the  exterior  of  the  building  at  a 
minimum height of eight (8) feet above grade directly in line 
with  the  exhaust  vent  terminal  for  the  horizontally  vented 
gas  fueled  heating  appliance  or  equipment.  The  sign  shall 
read,  in  print  size  no  less  than  one-half  (1/2)  inch  in  size, 
“GAS  VENT  DIRECTLY  BELOW.  KEEP  CLEAR  OF  ALL 
OBSTRUCTIONS.”
4.  Inspection. The  state  or  local  gas  inspector  of  the  side 
wall  horizontally  vented  gas  fueled  equipment  shall  not 
approve the installation unless, upon inspection, the inspector 
observes carbon monoxide detectors and signage installed 
in  accordance  with  the  provisions  of  248  CMR  5.08(2)(a)1 
through 4.
(b)  Exemptions:  The  following  equipment  is  exempt  from 
248 CMR 5.08(2)(a)1 through 4:
1.  The  equipment  listed  in  Chapter  10  entitled  "Equipment 
Not  Required  To  Be  Vented"  in  the  most  current  edition  of 
NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled 
equipment installed in a room or structure separate from the 
dwelling,  building  or  structure  used  in  whole  or  in  part  for 
residential purposes.
(c)  Manufacturer requirements — Gas Equipment venting 
System  Provided.
  When  the  manufacturer  of  Product 
Approved side wall horizontally vented gas equipment provides 
a venting system design or venting system components with 
the equipment, the instructions provided by the manufacturer 
for installation of the equipment and the venting system shall 
include:
1.  Detailed  instructions  for  the  installation  of  the  venting 
system design or the venting system components; and
2.  A  complete  parts  list  for  the  venting  system  design  or 
venting system.
(d)  Manufacturer  requirements  —  Gas  Equipment 
venting System Not Provided. 
When the manufacturer of 
a Product Approved side wall horizontally vented gas fueled 
equipment  does  not  provide  the  parts  for  venting  the  flue 
gases, but identifies “special venting systems,” the following 
requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall 
be  included  with  the  appliance  or  equipment  installation 
instructions; and
2. The “special venting systems” shall be Product Approved 
by the Board, and the instructions for that system shall include 
a parts list and detailed installation instructions.
(e)  
A copy of all installation instructions for all Product 
Approved side wall horizontally vented gas fueled equipment, 
all venting instructions, all parts lists for venting instructions, 
and/or all venting design