Monessen Hearth 624DV(ST User Manual

Page of 52
42D0200
Designer Series Gas Fireplaces
9
CLEaRaNCES
CLEaRaNCES To CoMBuSTIBLES 
MaNTEL CLEaRaNCES 
NoTE:  The  combustible  area  above  the  facing  must  not 
protrude  more  than  3/4"  from  the  facing.  If  it  does,  it  is 
considered a mantel and must meet the mantel requirements 
listed in this manual.
w
a
RNING
Follow these instructions carefully to ensure safe installation. Failure 
to follow instructions exactly can create a fire hazard.
The  appliance  cannot  be  installed  on  a  carpet,  tile  or  other 
combustible material other than wood flooring. If installed on carpet 
or vinyl flooring, the appliance shall be installed on a metal, wood 
or noncombustible material panel extending full width and depth of 
the appliance.
Figure 6 -  
Mantel Clearances 
2”
4”
6”
8”
10”
4”
6”
8”
10”
12”
FP2279
mantel clearance
2/09
Wall
Insulation Board
Standoff
Top of Louvers
FP2279
w
a
RNING
Never obstruct or modify the air inlet or outlet grills (louvers). This 
may create a fire hazard.
FINIShING MaTERIaL
NoTE: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to 
final finishing to avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating 
of Zero) may be used to cover the black-painted face of the appliance. A 300°F minimum adhesive 
may be used to attach facing materials to the black surface. If joints between the finished wall and 
the fireplace surround are sealed, a 300°F minimum sealant material (General Electric RTV103 or 
equivalent) must be used. Combustibles may come to the top and side edges but not overlay the 
face.