1.  STOP! Read the safety information label.
2.  Make sure the manual shutoff valve is fully open.
3.  Turn gas control knob clockwise 
 to the “OFF” position, and turn ON/OFF switch to 
“OFF” position.
4.  Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell 
gas, STOP!
5. From “OFF” position, turn the gas control knob counterclockwise 
  to “PILOT” position. 
Push in control knob for 5 seconds.
6.  With the control knob pushed in, light pilot with match. 
7.  Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from 
shutting off the gas while the probe is warming up. Release the control knob.
8.  Turn gas control knob counterclockwise
 to the “ON” position.
9.  After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF 
switch to “ON” position. 
10. If the gas logs will not operate, follow the instructions “To Turn Off Gas to Heater” and call your 
service technician or gas supplier.
Figure 148 - Control Knob
Figure 147 - Pilot
 
TO TURN OFF GAS TO HEATER
 
  1.  Turn control knob clockwise 
 to OFF position to completely shut off the heater.
  2.  If applicable: Turn ON/OFF switch to OFF position.
 MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS 
Figure 149 - On/Off Switch