reMOte cOntrOl OperatIOn
reMOte transMItter OperatIOns
General
Figure 39
The RFSC Remote Control has two (2) operating modes: Manual and Thermostatic. The control 
system can be set to a temperature range between 45° F and 90° F. The blower speed, light, 
rear burner shut down and flame height can be adjusted in either the manual and thermostatic 
mode.
The transmitter will operate the remote receiver from 12" to a maximum of 30'. nOte: The 
distance decreases when the batteries are low.
Initial startup
°F
▲ON ▲OFF
FAN
AUTO
LIGHT
AUX
AMBIENT
FP2141
signature remote
12/08
Figure 39 - 
Remote Transmitter
FP2141
FP2142
Figure 40 - 
Typical Reset Display
°F
FP2142
initial start up
FP2143
Figure 41 -
Manual Mode
°F
FP2143
manual mode
12/08
FP2144
Figure 42 - 
Thermostatic Mode
°F
FP2144
thermostat mode
12/08
°F
SET
Figure 40
1.  After initial power up or when RESET button is pressed, the transmitter is reset. The reset 
button is located behind the battery door of transmitter.
2.  During system reset, all features of the LCD DISPLAY will be visible. After one second, 
the LCD will be initialized. A typical reset display is shown in Figure 49. Note that the 
temperature scale is degree F.
3.  Press ON button to select between °C and °F display. It will exit setting mode automati-
cally after 10 seconds if no key is pressed. The transmitter will send an OFF signal after 
reset.
4.  After  reset,  the  transmitter  is  operating  in  manual  mode.  The  room  temperature  is 
shown.
Manual Mode
Figure 41
1.  Press the ON button once to turn on the appliance with max flame height.
2.  Press the OFF button to decrease flame height. The first two (2) presses will decrease 
flame height to lower level. The third press will turn off the fireplace.
3.  If OFF button is held for more than three (3) seconds, the fireplace will be shut off and 
remembers the last flame height setting. It will also remember light and auxiliary settings. 
To reset, change setting and hold OFF button for 3 seconds. New setting is now remem-
bered.
thermostatic Mode
Figure 42
1.  Press the AUTO button to enter the thermostatic mode. 
2.  In thermostatic mode, press the ON / ▲ button or OFF / ▼ button to set the desired set 
temperature.
3.  Once the setting is completed, the transmitter will automatically turn on the fireplace 
when the room temperature is below the set temperature and turn off the fireplace when 
the room temperature is above the set temperature within 1 degree.
4.  There will be a slight delay in the response of the unit (on/off) to a temperature. Room 
temperature is monitored every three (3) minutes.
5.  Press AUTO button to exit the thermostatic mode. The transmitter will be in the manual 
off mode and the fireplace will be shut off.
  nOte: When thermostat mode is used, the command center ON/OFF buttons will  not 
function, only the master switch will function.