Monessen Hearth 36CDVXTRN User Manual

Page of 44
19
CDVX Series Direct Vent Gas Fireplace
20012253
STEP 6
Support the horizontal pipes every 36” (914 mm) with 
metal pipe straps. Make sure that the horizontal vent 
pipe is installed on a level horizontal plane.
STEP 7
Re-check the fireplace to make sure that it is levelled, 
properly positioned, and nailed or screwed to the floor. 
If applied, the fireplaces adjustable frame drywall strips 
(nailing flanges) should be fastened. Refer to “Framing 
& Finishing”.
CFM137
Rear Vent length
2/26/01   sta
X
High 
Temperature Sealant
CFM137
Fig. 32  Apply high temperature sealant.
CFM138
4", 7" collar
2/26/01   sta
X
X
CFM138
Fig. 33   Horizontal length requirement.
Below Grade Installation
When it is not possible to meet the required vent ter-
minal clearances of 12” (305 mm) above grade level 
a snorkel vent kit #7TDVSNORK is required.  It allows 
installation depth of down to 7” (178 mm) below grade 
level.  The 7” is measured from the center of the hori-
zontal vent pipe as it penetrates through the wall.
If venting system is installed below 
ground, we recommend a window well with 
adequate and proper drainage.
Ensure sidewall venting clearances are observed.
The maximum horizontal run with 24” 
vertical rise is 36” (914 mm) from the 
back of the fireplace to the face of the 
exterior wall. See vent graph (Page 13)  for 
extended horizontal run if the vertical rise 
exceeds 24” (610 mm).
1.  Establish vent hole through the wall. (Fig. 17)
2.  Remove soil to a depth of approximately 16” 
(406mm) below base of snorkel. Install window 
well (not supplied). Refill hole with 12” (305 mm) of 
coarse gravel leaving a clearance of approximately 
4” (102 mm) below snorkel. (Fig. 34)
3.  Install vent system. See Page 14, Steps 2 through 5.
4.  Ensure a watertight seal is made around the vent 
pipe coming through the wall.
5.  Apply high temperature sealant caulking around the 
4” and 7” snorkel collars.
6.  Slide into the vent pipe and secure to the wall.
7.  Level the soil to maintain a 4” (102 mm) clearance 
below snorkel. (Fig. 34)
BG400
Below grade installation
2/10/99   djt
10/19/99  added standoffs
24" (610mm)
Minimum*
Firestop
7” Pipe
7TDVSNORK 
(Snorkel)
4” (102mm) 
Clearance 
Min.
Window 
Well
Gravel
Drain
Foundation Wall
BG400
Fig. 34   Below grade installation.
*A minimum of 24” (608mm) 
vertical pipe must be installed 
when using 7TDVSNORK Kit.