Monessen Hearth 36CDVXTRN User Manual

Page of 44
39
CDVX Series Direct Vent Gas Fireplace
20012253
FK12
This auxiliary fan system increases the efficiency of the 
circulation of the heating air. 
The FK12 Fan Assembly is a fixed speed fan system 
and does not allow for variable speed control.
Specifications
115 Volts / 60 Hz / 56 Watts.
Maintenance
The fan itself does not require regular maintenance, 
however periodic cleaning of the fan and the 
surrounding area is required. 
Check the area under the control door (lower louvre 
assembly) and in front of the fan and wipe or vacuum 
this area at least once a month during the operating 
season.
Installation
The fan assembly is supplied fully wired eliminating 
the need for a licensed electrician to carry out the 
installation.
1.  Remove the lower Louvre assembly. Move the 
fan & bracket assembly around the gas valve and 
lines to locate the unit against the back wall of the  
appliance, resting on the base.
2.  With the protective cover removed from the self-
adhesive ‘Velcro’ strips apply mild pressure to the 
fan & bracket unit to secure the strips to the metal 
panels. No further securing is required. 
3.  Power to the fan can be supplied by plugging the 
supplied lead into a conveniently located wall socket 
or by using the receptacle in the bottom of the unit.
Optional Accessories Available
Fan Kits
FP1602
FK12
fan install
12/05
Fan
Gas Lines
Valve
FP1602
Fig. 76  FK12 fan placement.
Receptacle
The fireplace, when installed, must be 
electrically connected and grounded in 
accordance with local codes or, in the 
absence of local codes, with the current 
CSA C22.1 Canadian Electric Code.
For USA installations follow the local 
codes and the national electrical code 
ANSI/NFPA No. 70.
Should this fan require servicing or repair 
the power supply must be disconnected. 
Any electrical rewiring of this fan must be 
done by a licensed electrician.
 
Wiring Instructions
Remote Controls
Optional remote control units are available to control 
different functions of the appliances.
 
Model 
Function/s Controlled
 
RCI 
ON/OFF
 
RC2 
ON/OFF and Temperature
 
IMTFK 
Wall mounted thermostat control  
 
(must be used in bedroom installations)
Optional Trim
The Perimeter trim is designed to enhance the look of 
the fireplace.
 
Model 
Description
 
36CDVTK 
Perimeter Trim  Black