Monessen Hearth BBV400 User Manual

Page of 40
62D4036
24
BBV, SBV Series Natural Vent Gas Fireplaces
LG663
BBV SBV400 log flame
LG663
CLEANING and MAINTENANCE
W
ARNING
Turn off gas before servicing fireplace. It 
is recommended that a qualified service 
technician  perform  these  check-ups  at 
the beginning of each heating season.
BURNER, PILOT AND CONTROL COMPARTMENT
Keep the control compartment, logs and burner areas surrounding the logs 
clean by vacuuming or brushing at least twice a year. Make sure the burner 
porting, pilot air opening and burner air openings are free of obstructions at 
all times.
PILOT FLAME
The flames from the pilot should be visually checked as soon as the heater is 
installed and periodically during normal operation. The pilot flame must always 
be present when the fireplace is in operation. Figure 26. The pilot flame has 
three distinct flames, one engulfing the thermopile, one engulfing the thermo-
couple and the other reaching to the main burner.
BURNER
Inspect area around the injector. Remove any lint or foreign material with a 
brush or vacuum.
BURNER FLAME
The  flames  from  the  burner  should 
be  visually  checked  as  soon  as  the 
heater  is  installed  and  periodically 
during  normal  operation.  In  normal 
operation, at full rate, and after oper-
ating for about 15 to 30 minutes, the 
flame  should  be  yellow  and  slightly 
taller than the rear log. Figure 27
NOTE:  The  type  of  installation, 
vent  system  configuration  and 
wind effects may cause the flame 
patterns to vary.
&0
PILOT
Thermocouple
Thermopile
FP2030
Figure 26 - 
Pilot Flame
Figure 27 - 
Burner Flame Appearance