54D0700
VENT INSTALLATION 
BELOW GRADE INSTALLATIONS
When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recommended. 
It allows installation depth down to 7" (178mm) below grade level. The 7" (178mm) is measured from the center of the 
horizontal vent pipe as it penetrates through the wall.
Ensure that sidewall venting clearances are observed. If venting system is installed below ground, we recommend a 
window well with adequate and proper drainage to be installed around the termination area.
If installing a snorkel, a minimum 24" vertical rise is necessary. The maximum horizontal run with the 24” vertical pipe is 
36". This measurement is taken from the collar of the fireplace (or transition elbow) to the face of the exterior wall. See the 
Sidewall Venting Graph for extended horizontal run if the vertical exceeds 24".
1.  Establish vent hole through the wall. See Figure 16, page 18. 
2.   Remove soil to a depth of approximately 16" below base of snorkel. Install drain pipe. Install window well (not supplied). 
Refill hole with 12" of coarse gravel leaving a clearance of approximately 4" below snorkel. See Figure 26.
3.   Install vent system.
4.   Ensure a watertight seal is made around the vent pipe coming through the wall.
5.   Apply high temperature sealant caulking (supplied) around the 4" and 7" snorkel collars.
6.   Slide the snorkel into the vent pipes and secure to the wall.
7.   Level the soil so as to maintain a 4" clearance below snorkel. See Figure 26.
• Do not back fi ll around snorkel.
• A clearance of at least 4" must be 
maintained between the snorkel and 
the soil.
W
ARNING
If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to 
wall first, then secure to snorkel with self drilling #8x
1
/
2
 sheet metal screws. It will be necessary to extend vent pipes out as 
far as the protruding wall face. See Figure 27.
Figure 27 - Snorkel Installation, 
Recessed Foundation
Figure 26 -  Below Grade Installation
Screws
Minimum 
4" Clearance
Ground
Window Well 
Gravel 
Drain 
Foundation Wall 
Firestop 
24"
Minimum 
Foundation
Recess 
Watertight Seal 
Around Pipe 
Sheet Metal 
Screws 
Wall Screws 