Monessen Hearth BDV300 User Manual

Page of 52
14 
54D0700
VENT INSTALLATION 
OPTIONAL TOP VENT APPLICATION 
The appliance is shipped as a rear vent unit. If the installation 
layout requires the unit to be a top vent configuration the appli-
ance can be converted by following the steps below.
When removing and refitting the plates and adapter be sure the 
associated gaskets are undamaged and refitted as required.
1.   Remove the eight (8) screws securing the flue pipe adapter 
to the fireplace body. See Figure 8. 
2.   Set the flue pipe adapter aside, complete with the gasket. 
Do not damage the gaskets as the adapter and gasket must 
be refitted.
3.   Remove the eight (8) screws securing the flue pipe cover to 
the top of the intake box and remove the cover and gasket. 
See Figure 8.
4.   Remove the six (6) screws securing the flue pipe to the 
back of the intake box and remove the pipe and gasket. 
See Figure 9.
5.   Replace flue pipe to top of firebox. Ensure the gasket is 
in place and undamaged.  Secure with six (6) screws. See 
Figure 10.
6.   Place the flue pipe cover and gasket removed in step 3 
over the flue opening in back of the intake box.
7.   Refit the flue pipe adapter and gasket to the top of fire-
place. Secure the adapter with eight (8) screws removed 
in step 1.
A f t e r   c o n v e r s i o n   t o   t o p   v e n t 
confi guration the 4" (100mm) fl ue pipe 
should be concentric within the 6
5
/
8
(175mm) outer collar (within 
1
/
4
").
W
ARNING
Figure 8 - Removing sixteen (16) Screws from 
Flue Pipe Adapter and Flue Pipe Cover 
Figure 9 - Removing Flue Pipe
Figure 10 - Attaching Flue Pipe to Top 
Vent Confi gurations  
Screws 
Flue Pipe 
Cover 
Flue Pipe 
Adapter 
Flue Pipe 
Screws
Flue 
Cover 
Flue Pipe 
Screws