VENT INSTALLATION: 
 
WARNING 
The following venting instructions are provided as a general guideline.  Always check with pipe manufacturer 
for venting requirements. 
 
Positioning The Fireplace: 
 
NOTE 
The fireplace must be installed giving full consideration to the clearance and height requirements identified 
in this manual. 
 
1.  Bend out the four (4) nailing flanges located on the sides of the fireplace.  For 5/8” drywall use the two (2) outer 
most flanges.  For ½” drywall use the two (2) inner flanges.  
2.  Slide the firebox into prepared framing or position fireplace in its final position and frame later. Be sure 
fireplace is resting on a flat surface. 
3.  Set unit level and plumb by checking the top and front of unit. Shim side-to-side and front-to-back as necessary. 
4.  Anchor nailing flanges of the fireplace to the side-framing members using 8d nails or other suitable fasteners. 
 
Venting Configuration: 
 
WARNING 
Never use 90 degree elbows 
 
WARNING 
This natural vent fireplace has been tested to use 8” Class B-Vent pipe 
 
Vertical Venting Straight up (No Elbow): 
  
 
 
 
 
                              Figure 6: Vertical Venting – Straight Up