FINAL INSTALLATION 
 
Wall Finishing: 
 
Definitions: 
 
Combustible Materials - Materials made of or surfaced with wood, compressed paper, plant fibers, or other 
materials that are capable of being ignited and burned. Such materials are considered combustible even 
though flameproof, fire retardant, treated, or plastered. 
 
Non-Combustible Materials - Materials which will not ignite and burn. Such materials are those consisting 
entirely of steel, iron brick, tile, concrete, slate, glass, marble, or combination thereof, or have a UL Fire 
rating of Zero (0). 
 
High Temperature Sealant Material - Sealant that will withstand high temperature; General Electric 
RTV103 or equivalent. 
 
Finishing the fireplace flush with a wall: 
 
When finishing the face of the fireplace, combustible material may be brought up to the side or top edge of the 
fireplace, but must never overlap the black metal face. The black metal face may be covered with non-combustible 
material only.  After applying the finishing material, a non-combustible sealant, 1/8” minimum, should be used to 
close off any gaps at the top and sides between the fireplace and the finishing to prevent cold air leaks. Refer to 
Figure 5: Finishing Material section in this manual for allowable locations for combustible materials. 
 
Rock Wool Placement: 
 
Rock wool should be evenly covering the burner from front to back.  The rock wool should be separated into chunks 
about the size of a nickel.  The bag supplied has an excess of rock wool.  The remaining may be used as filler over 
time. 
 
Lava Rock Placement: 
 
Sprinkle a thin layer of lava rock on the floor of the inner chamber. DO NOT pile up in any area. It should be 
placed in a single layer only around but not on any portion of the burner. 
 
          
WARNING 
Do not sprinkle the lava rock on top of the burner.  This may cause potential sooting, glass breakage and/or a 
fire hazard