Monessen Hearth BWBC400MHB User Manual

Page of 40
10 
61D0087
52" (400 Models)
66" (500 Models) 
16" Min.
(400 Unit)
20" Min.
(500 Unit)
21"
21
1
/
2
"
40
1
/
2
"
40
1
/
8
" (400 Unit)
46
1
/
8
" (500 Unit)
SAFETY STRIP INSTALLATION 
You must place the metal safety strip (packed with your fireplace in two pieces) beneath the fireplace front before installing 
hearth extension Slide  safety strip approximately 1
1
/
2
" under the fireplace. The hearth extension will install on top of the 
safety strip. See Figures 8 and  9. 
HEARTH EXTENSION
For manufactured home installations, use the Model H1652 (400 unit) or Model H2066 (500 unit) hearth extension or an 
equivalent hearth extension* acceptable to the authority having jurisdiction. The hearth extension must cover an area 16" 
(400 unit) or 20" (500 unit) in front of, and 8" either side of the fireplace opening. See Figures 8 and 9. If a raised hearth 
extension is desired, the fireplace must be elevated accordingly and positioned on a platform constructed of combustible or 
noncombustible materials.
The hearth extension may be covered with tile or any noncombustible material. The hearth extension assembly must not 
block lower louvered panel.
Note:  Do not install hearth extension until after fireplace and chimney have been installed. 
FIREPLACE INSTALLATION
Figure 8 - Installing Hearth Extension 
Gas 
Opening 
Junction 
Box 
Opening 
Floor 
Level 
Safety 
Strip
Hearth 
Extension 
   Hearth Extension Clearances & Width 
400 Unit
500 Unit
On Both Sides
8" Min.
8" Min.
Front of Fireplace
16" Min.
20" Min.
Extension Width
52"
66"