WOOD VS. FOSSIL FUELS
Compared to fossil fuels, a full cord of dry hickory weighs 
about two tons and is approximately equal in heating value 
to a ton of hard coal. On a per pound basis, heavy hardwoods 
have about half the heating value of coal. The table below 
shows the relative densities and heat values of a variety of 
dry woods. Varieties at the top of the list (Dogwood) burn 
longer and those near the bottom (White Pine) ignite and 
burn quicker. A combination of both light and heavy wood 
is desired.
  SPECIES VALUE 
DENSITY 
HEAT 
  Dogwood 
.70-.79 
100-107
  Hickory 
.70-.74 
100
  Oak 
.60-.73 
86-99
  Black Locust 
.69-.70 
95-98
  Beech 
.64-.66 
89-91
  Hard Maple 
.58-.65 
83-88
  Birch 
.55-.64 
79-86
  Apple 
.58-.62 
83-84
  Ash 
.57-.61 
81-82
  Southern Pine 
.51-.60 
73-81
  Elm 
.50-.59 
71-80
  Cherry 
.50-.52 
70
  Douglas Fir 
.45-.51 
64-69
  Spruce 
.41-.44 
59
  Redwood 
.33-.40 
47-54
  White Pine 
.35-.37 
50
BUILDING AND TENDING A FIRE
The first three fires should be of moderate size to allow the 
fireplace to adjust and cure before being subjected to larger 
fires.
First, make sure your room is well ventilated, your damper 
open and the flue is unobstructed. Then make sure your wood 
is dry and seasoned. Unseasoned wood burns poorly. If you 
use unseasoned wood with poor ventilation or an obstructed 
chimney, smoking could occur. 
Open the outside combustion air damper by pushing upward 
on its control lever located above the firebrick on the left side 
of the firebox. This damper should be open while the fireplace 
is in use. See Figure 5, page 7.
The flue damper control lever is located just below the upper 
grille of the fireplace. You can reach the control lever through 
the front opening of the fireplace. The damper is operated by 
simply unlocking up to open or pulling and locking down 
to close.
The  flue  damper  is  counterweighted 
to  maintain  the  fully  open  position. 
The  flue  damper  must  be  fully  pen 
while the fireplace is in use. The flue 
damper must be open unless the fire 
is completely out and all smoking has 
stopped. 
W
ARNING
Never  use  gasoline,  gasoline-type 
lantern fuel, kerosene, charcoal lighter 
fluid,  or  similar  liquids  to  start  or 
“freshen  up”  a  fire  in  this  fireplace. 
Keep all such liquids well away from 
the  fireplace  while  it  is  in  use.  Use 
of  this  fuel  can  cause  a  serious 
explosion.
W
ARNING
FIREPLACE OPERATION