Regency P40-NG User Manual

Page of 48
Regency
®
 P40 Direct Vent Gas Fireplace
15
INST
ALLA
TION
INSTALLATION
RIGID PIPE VENTING SYSTEMS
BASIC HORIZONTAL & VERTICAL TERMINATIONS
Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered 
in decorative black, as well as galvanized fi nish. 
The minimum components required for a basic 
horizontal termination are:
 1 Horizontal 
Termination 
Cap
 1 90
o
 Elbow 
 1 Rigid 
Pipe 
Adaptor
 1 Wall 
Thimble 
(Canada 
only) 
  1  Length of pipe to suit wall thickness 
The minimum components required for a basic 
vertical termination are:
 1 Vertical 
Termination 
Cap
 1 Rigid 
Pipe 
Adaptor
  1  Lengths of pipe to adequately
   penetrate 
roof
 1 Ceiling 
Firestop
 1 Flashing
 1 Storm 
Collar
Wall thickness  is measured from the back 
standoffs to the inside mounting surface of 
termination cap. For siding other than vinyl 
furring strips may be used, instead of the vinyl 
siding standoff, to create a level surface to 
mount the vent terminal. The Terminal must 
not be recessed into siding. Measure the wall 
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must 
be used with vinyl siding), measure to outside 
surface of wall without siding and add 2 
inches.
Rigid Pipe Adapter
(770-994)
Pipe Length
Vertical
Terminal
Storm Collar
Flashing
Ceiling Firestop
24" Pipe
Length
Adj.Pipe Length
11" - 14-5/8"
90 Elbow
o
AstroCap XL
Termination Cap
(946-623/P)
Wall Thimble
(required in Canada only)
Vinyl Siding
Standoff
      
This product has been evaluated by Intertek for 
using a Rigid Pipe Adaptor in conjunction with 
Duravent Direct-Vent GS and Selkirk Direct-
Temp systems. Use of these systems with 
the Rigid Pipe adaptor is deemed acceptable 
and does not affect the Intertek WHI listing of 
components.
WARNING:
Do not combine venting components from 
different venting systems.
Use of the the AstroCap XL
TM
 and FPI Riser is 
acceptable with all systems.
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be 
used to secure rigid pipe to adaptor.
The FPI AstroCap XL
TM 
is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent
®
 Direct Vent GS and Selkirk Direct-Temp. 
AstroCap XL
TM
 is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary 
trademarks of Simpson Dura-Vent Co. Inc.
Alternate 
Horizontal Termination 
Caps