Regency L676S-LP1 User Manual

Page of 3
L676-1 Sunrise Gas Fireplace
Regency L676-1 Sunrise Gas Fireplace
Model
L676S-NG1
L676S-LP1
Fuel Type
Natural Gas
Propane
Minimum Supply Pressure
5” W.C. (1.25 kPa)
12” W.C. (2.98 kPa)
Manifold Pressure - High
3.5” W.C. (0.87 kPa)
10” W.C . (2.49 kPa)
Manifold Pressure - Low
1.6” W.C. (0.40 kPa)
6.4” W.C (1.59kPa)
Orifi ce Size
#37 DMS
#53 DMS
Minimum Input 
Altitude 0-4500 ft. (0-1372m)
19,500 BTU/h  
(5.71 kW)
21,000 BTU/h
(6.15kW)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
29,000 BTU/h
(8.49 kW)
26,000 BTU/h
(7.61kW)
Vent Sizing
5” Inner / 8” Outer
5” Inner / 8” Outer
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems:
Simpson Direct Vent Pro®
Selkirk Direct-Temp™
Metal-Fab® Sure Seal
Unit Dimensions
Description
L676S-1
A
Firebox Width w/ Standoff
42-1/2” (1080mm)
B
Rear Firebox Width
33-1/8” (841mm)
C
Firebox Height
37-3/8” (949mm)
D
Height w/ Standoff
45-5/8” (1159mm)
E
Unit Depth
24” (610mm)
F
Height to Vent
40-3/8” (1026mm)
G
Fireplace Opening Height 
29-1/16” (738mm)
H
Fireplace Opening Width
31-5/8” (803mm)
I
Height to Fireplace Opening
3” (76mm)
Unit Dimensions:
Framing Dimensions
Description
L676S-1
J
Framing Width
43” (1092mm)
K
***
Framing Height
***
45-7/8” (1165mm)
*** 
+ Hearth
L
Framing Depth
24-1/2” (622mm)
M
Minimum Height to Combustibles
56-1/4” (1429mm)
N
Corner Wall Length
57-3/16” (1453mm)
O
Corner Facing Wall Width
80-13/16” (2052mm)
P
 Vent Centerline Height
49-1/4” (1251mm)
Q
 Non-combustible Facing Height
15-9/16 (395mm)
R
Gas Connection Opening Height
2” (51mm)
S
Gas Connection Height
11-1/4” (286mm)
T
Gas Connection Inset
5-3/4” (146mm)
U
Gas Connection Opening Width
5” (127mm) 
***
Important:  Framing height requires consideration of the hearth 
depth.   Dimension K = K + the thickness of installed hearth.
Framing Dimensions:
Non-Combustible Requirements:
47-5/8"
(1209mm)
6-7/16"
(163mm)
3"
(76mm)
32-1/16”
(814mm)
15-9/16"
(392mm)
29-1/16”
(738mm)
31-5/8"
(803mm)
44-1/2"
(1130mm)
Non-combustible
Material
Non-combustible Material
Non-combustible
Material
Non-combustible
Material
Metal
Stud
Finished Floor
WARNING
Failure to maintain required clearances is a major cause of chimney related fi res.  
Installation of this fi replace must comply with these clearances
Please note:
 Due to ongoing product development, product appearance and specifi cations 
are subject to change without notice.
This manual is intended to be a Sales Reference Guide only.
Do NOT use for actual framing and installation of any unit. 
Some specifi cations may change without notice.
You must use the actual manual for exact installation specifi cations.