Regency Wraps P36-LPG4 User Manual

Page of 44
Regency
®
 P36-4 Gas Log Fireplace
34
10) Undo the pilot tube from the valve with a 
7/16" spanner.
11) Undo the quick drop out thermocouple nut 
on the valve with a 9mm (metric) spanner.
12) Remove the Piezo igniter wire and push 
button assembly.  
13) Undo the "gas out" fl are nut with a 13/16" 
spanner.
14) Undo the "gas out" fl are fi tting with an 11/16" 
spanner.
15) Remove the 4 Phillips head screws from 
the sides of the valve bracket and remove 
valve.
Hint: 
If you are using black pipe, ensure 
that there is a union by the valve, 
otherwise removal will be almost 
impossible.
INSTALLING VALVE
1)  Attach the valve to the valve bracket with 
the 4 (m5x8 metric) screws provided.
2)  Reconnect the "gas out" fl are fi tting with an 
11/16" spanner.
3)  Reconnect the "gas out" fl are nut with a 
13/16" spanner.
4)  Install piezo ignitor push button assembly 
and reconnect wire.
5)  Reconnect the quick drop out thermocouple 
nut with a 9mm spanner.
6)  Reconnect the pilot tube nut with a 7/16" 
spanner.
7)  Scrape off the old gasket from the fl oor of the 
fi rebox and from the valve tray assembly.
8)  Install a new gasket and reinstall the valve 
tray assembly.
Note:  Failure to install a new gasket 
may severely affect the appliance 
performance.
9)  Reinstall the 10 hold down screws.
10) Hook up the 2 TP and 2 TH wires to the 
appropriate connections on the valve.
11) Reinstall the front log stand.
12) Install Burner/grate assembly
13) Hook up the gas line and check for gas 
leaks with a soap and water solution or a 
gas leak detector. (Do not use open fl ame 
for leak testing.)
14) Fire up the unit temporarily
15) Check the manifold pressure.
16) Reinstall the logs and brick panels as 
needed.
17) Close the door and replace the louvres.
18) Fire up the unit again and check for proper 
fl ame appearance and glow on logs.
REMOVING VALVE
1)  Shut off the gas supply.
2)  Remove the louvres (and bay door if it is 
on).
3)  Open the fl ush door and remove the door.
4)  Remove the logs.
5)  Remove the burner/grate assembly by 
removing the two Phillips head screws and 
then lift the burner assembly out.
Diagram 1: Remove the left and right screws 
and then lift out the burner/grate assembly.
6)  Remove the rear log stand by removing the 
2 screws.
Diagram 2: Rear Log Stand and
Valve Tray Assembly
screws
Valve Tray Assembly
Rear Log Stand
screws
7)  Disconnect the inlet gas line. See diagram 
2.
8)  Disconnect the 2 TP wires and the 2 TH 
wires from the valve.
9)  Remove the 10 Phillips head screws securing 
the valve tray assembly in place (diagram 2) 
and then lift the entire assembly out  diagram 
3).
MAINTENANCE