Note: To assure top performance, safety and effi ciency, 
inserts must be installed with an approved fl ue liner as per 
CAN/CGA B-149 or National Fuel Gas Code ANSI Z223  and 
these instructions.
Note:  This installation must conform with local codes. In the 
absence of local codes you must comply with the National 
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and 
the CAN/CGA B149 Installation Codes in Canada.
Listing and Code Approvals 
 
C. High Altitude Installations
U.L. Listed gas appliances are tested and approved with-
out requiring changes for elevations from 0 to 2000 feet 
in the U.S.A. and Canada.
When installing this appliance at an elevation above 
2000 feet, it may be necessary to decrease the input rat-
ing by changing the existing burner orifi ce to a smaller 
size. Input rate should be reduced by 4% for each 1000 
feet above a 2000 foot elevation in the U.S.A., or 10% for 
elevations between 2000 and 4500 feet in Canada. If the 
heating value of the gas has been reduced, these rules 
do not apply. To identify the proper orifi ce size, check 
with the local gas utility.
If installing this appliance at an elevation above 4500 feet 
(in Canada), check with local authorities.
B. BTU Specifi cations
MODELS:  QVI30S, QVI35S
LABORATORY:  Underwriters Laboratories, Inc. (UL)
TYPE:  Vented Gas Appliance Heaters
STANDARD: ANSI Z21.88-2000 • CSA2.33-M00 • UL307B
Do NOT use this appliance if any part has been under water. 
Immediately call a qualifi ed service technician to inspect the 
appliance and to replace any part of the control system and 
any gas control which has been under water.
This product is listed to ANSI standards for “Vented Gas 
Appliance Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and 
Recreational Vehicles”, and “Gas Fired Appliances for 
Use at High Altitudes”.
Models
(U.S. or Canada)
Maximum
Input 
BTU/h
Minimum
Input 
BTU/h
Orifi ce
Size 
(DMS)
QVI30S (NG)
US
(0-2000 FT)
32,000
22,000
#35
CANADA
(2000-4500 FT)
28,800
19,800
#36
QVI35S (NG)
US
(0-2000 FT)
35,500
23,500
#32
CANADA
(2000-4500 FT)
31,950
21,150
#33
QVI30S (LP)
US
(0-2000 FT)
31,000
18,000
#52
CANADA
(2000-4500 FT)
27,900
16,200
#53
QVI35S (LP)
US
(0-2000 FT)
31,000
19,000
#51
CANADA
(2000-4500 FT)
27,900
17,100
#52
A. Appliance Certifi cation
D.  Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are 
those consisting entirely of steel, iron, brick, tile, concrete, 
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136, 
Standard Test Method for Behavior of Materials in a 
Vertical Tube Furnace at 750º C, 
shall be considered 
non-combustible materials.
E.  Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed 
paper, plant fi bers, plastics, or other material that can ig-
nite and burn, whether fl ame proofed or not, or whether 
plastered or unplastered shall be considered combustible 
materials.
WARNING
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.  
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance.  It should not be 
factored as primary heat in residential heating calculations.
F. Electrical Codes
NOTICE:  This appliance must be electrically wired 
and grounded in accordance with local codes or, in the 
absence of local codes, with 
National Electric Code 
ANSI/NFPA 70-latest edition
 or the Canadian Electric 
Code CSA C22.1.
• 
A 110-120 VAC circuit for this product must be protected 
with ground-fault circuit-interrupter protection, in 
compliance with the applicable electrical codes, when it is 
installed in locations such as in bathrooms or near sinks.  