Installing the Fireplace
Step 1.  Locating the Fireplace
The diagram below shows space and clearance require-
ments  for locating a fi replace within a room.
 A 
E
  35 1/2” 
21 3/4” 
30 1/2” 
43 1/4” 
61 3/16”
 (902 mm) 
(552 mm)  (775 mm)  (1099 mm)  (1554 mm)
Minimum Clearances
 from the Fireplace to Combustible Materials
  
Inches 
mm
Glass Front .........................36  ..............914 
Floor  
.............................0 
..................0   
Rear  
........................... 1/2 
................13   
Sides  
........................... 1/2 
................13   
Top  
..........................4 
1/2 
............. 114 
 
Ceiling*  
............................31 
...............787
Figure 2.  Fireplace Dimensions, Locations, and 
Space Requirements
Framing should be 
constructed of 2 X 4 
lumber or heavier.
A. ..... 35-1/8”  (892 mm)
B. ..... 50-1/2”  (1283 mm)
C. ..... 21-3/8”  (542 mm)
D. ..... 55-1/2”  (1372 mm)
Figure 3.  Framing Dimensions
For minimum clearances, see the direct vent termination 
clearance diagrams on pages 20 and 21 in this manual.
Minimum Clearances
 from the Vent Pipe to Combustible Materials
  
Inches 
mm
Vertical Sections. .............. 1    ................ 25
Horizontal Sections
Top ...................................... 3  ................. 75
Bottom ................................ 1 ................. 25
Sides................................... 1 ................. 25
At Wall Firestops
Top ...................................... 3  ................. 76
Bottom ................................ 1 ................. 25
Sides................................... 1 ................. 25
A
B
4” (102 mm)
D
C
E
1/2” (13 mm) 
Shows center of
10” x 12” vent framing 
holes for venting.
C
B
A
D
 *  The clearance to the ceiling is measured from the 
top of the unit, excluding the stand-offs and collar. 
See Figure 24 for further details.
(Center of 12 x 10)
Clearance Requirements
The top, back, and sides of the fi replace are defi ned  by 
stand-offs. The minimum clearance to a perpendicular wall 
extending past the face of the fi replace is 4 inches (102 
mm). The back of the fi replace may be recessed 23 (584 
mm) inches (546 mm) into combustible construction.
Step 2.  Framing the Fireplace
Fireplace framing can be built before or after the fi replace is 
set in place. Framing should be positioned to accommodate 
wall coverings and fi replace facing material. The diagram 
below shows framing reference dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS, AND 
VERIFY FRAMING METHODS AND WALL COVERING 
DETAILS, BEFORE FRAMING.
The distance from the unit to combustible construction is 
to be measured from the unit outer wrap surface to the 
combustible construction, NOT from the screw heads 
that secure the unit together.