Hearth & Home Technologies Everest User Manual

Page of 29
Heat & Glo  •  Everest  •  750-900  Rev. o  •  10/08
16
Figure 10.  Vertical Baffl e  
1.  Attach the First Vent Component to the
     Starting Collars
To attach the fi rst vent component to the starting collars 
of the fi replace:
•  Make sure that the fi replace gasket supplied with the 
fi replace seals between the fi rst component and the outer 
fi replace wrap.
•  Refer to Cinch Pipe and Termination Cap installation 
instructions.
B.  Installing Vent Components 
If your vertical vent component is over 10 feet, you may 
want to install the included vertical baffl e to improve fl ame 
appearance. Vertical baffl e is located in the bag containing 
the instruction manual. Center the vertical baffl e on the fi ve 
inch vent being used, and with self tapping screws secure 
the baffl e to the inside of the fi rebox  (see Figure 10).
With vent runs of 30 feet or more without elbows, an 
additional baffl e (SRV750-152) is to be used with the 
supplied baffl e. This is a service part and is to be purchased 
separately.
VERTICAL
BAFFLE
5” EXHAUST
PIPE
2.  Assembling Vent Sections
Refer to Cinch Pipe and Termination Cap installation in-
structions.
!
WARNING: ENSURE THAT THE FIBERGLASS 
GASKET SUPPLIED WITH THE FIREPLACE 
SEALS BETWEEN THE FIRST VENT COMPO-
NENT AND THE OUTER FIREPLACE WRAP.
If the installation is for a termination cap attached directly 
to the fi replace, skip to the sections, Install Firestops and 
Vent Termination.