H.  Requirements for the Commonwealth of
Massachusetts
For all side wall horizontally vented gas fueled equipment 
installed in every dwelling, building or structure used in 
whole or in part for residential purposes, including those 
owned or operated by the Commonwealth and where the 
side wall exhaust vent termination is less than seven (7) 
feet above finished grade in the area of the venting, in-
cluding but not limited to decks and porches, the following 
requirements shall be satisfied:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented 
gas fueled equipment, the installing plumber or gas fitter 
shall observe that a hard wired carbon monoxide detector 
with an alarm and battery back-up is installed on the floor 
level where the gas equipment is to be installed. In addi-
tion, the installing plumber or gas fitter shall observe that 
a battery operated or hard wired carbon monoxide detec-
tor with an alarm is installed on each additional level of 
the dwelling, building or structure served by the side wall 
horizontal  vented  gas  fueled  equipment.  It  shall  be  the 
responsibility of the property owner to secure the services 
of  qualified  licensed  professionals  for  the  installation  of 
hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fu-
eled equipment is installed in a crawl space or an attic, 
the hard wired carbon monoxide detector with alarm and 
battery  back-up  may  be  installed  on  the  next  adjacent 
floor level.
In the event that the requirements of this subdivision can 
not be met at the time of completion of installation, the 
owner shall have a period of thirty (30) days to comply 
with the above requirements; provided, however, that dur-
ing said thirty (30) day period, a battery operated carbon 
monoxide detector with an alarm shall be installed.
Approved Carbon Monoxide Detectors
Each  carbon  monoxide  detector  as  required  in  accor-
dance with the above provisions shall comply with NFPA 
720 and be ANSI/UL 2034 listed and IAS certified. 
Signage
A metal or plastic identification plate shall be permanent-
ly mounted to the exterior of the building at a minimum 
height of eight (8) feet above grade directly in line with the 
exhaust vent terminal for the horizontally vented gas fu-
eled heating appliance or equipment. The sign shall read, 
in print size no less than one-half (1/2) in. in size, 
“GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB-
STRUCTIONS”.
Inspection
The state or local gas inspector of the side wall horizon-
tally vented gas fueled equipment shall not approve the 
installation  unless,  upon  inspection,  the  inspector  ob-
serves carbon monoxide detectors and signage installed 
in accordance with the provisions of 248 CMR 5.08(2)(a)1 
through 4. 
Exemptions
The  following  equipment  is  exempt  from  248  CMR 
5.08(2)(a)1 through 4: 
•  The equipment listed in Chapter 10 entitled “Equipment 
Not Required To Be Vented” in the most current edition 
of NFPA 54 as adopted by the Board; and 
•  Product Approved side wall horizontally vented gas fu-
eled equipment installed in a room or structure separate 
from the dwelling, building or structure used in whole or 
in part for residential purposes. 
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When  the  manufacturer  of  Product Approved  side  wall 
horizontally  vented  gas  equipment  provides  a  venting 
system  design  or  venting  system  components  with  the 
equipment, the instructions provided by the manufacturer 
for installation of the equipment and the venting system 
shall include:
•  Detailed instructions for the installation of the venting 
system design or the venting system components; and
•  A complete parts list for the venting system design or 
venting system. 
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall 
horizontally vented gas fueled equipment does not pro-
vide  the  parts  for  venting  the  flue  gases,  but  identifies 
“special  venting  systems”,  the  following  requirements 
shall be satisfied by the manufacturer:
•  The  referenced  “special  venting  system”  instructions 
shall be included with the appliance or equipment in-
stallation instructions; and 
•  The  “special  venting  systems”  shall  be  Product  Ap-
proved by the Board, and the instructions for that sys-
tem  shall  include  a  parts  list  and  detailed  installation 
instructions. 
A copy of all installation instructions for all Product Ap-
proved  side  wall  horizontally  vented  gas  fueled  equip-
ment,  all  venting  instructions,  all  parts  lists  for  venting 
instructions,  and/or  all  venting  design  instructions  shall 
remain with the appliance or equipment at the completion 
of the installation. 
See Gas Connection section for additional Common-
wealth of Massachusetts requirements.
Note:  The  following  requirements  reference  various 
Massachusetts  and  national  codes  not  contained  in  this 
document.