Hearth & Home Technologies ESCAPE-42DV User Manual

Page of 57
Heat & Glo  •  Escape-42DV  •  2052-900  Rev. R  •  10/08
10
NON-COMBUSTIBLE
MATERIAL
4 INCH
MINIMUM
UNLIMITED
D. Mantel Projections
Figure 3.3  Clearances to mantels or other combustibles  
 above 
appliance
Figure 3.4  Clearances to Mantel Legs or Wall Projections  
 
(Acceptable on both sides of opening.)
NO COMBUSTIBLES
IN THIS AREA
3-1/2 IN.
COMBUSTIBLE
FRAMING
COMBUSTIBLE
PROJECTIONS
METAL PANELS
(PROVIDED)
39 IN.
11-12 IN.
NON-COMBUSTIBLE
FACING MATERIAL
MIN. 1/2 IN. THICKNESS
TOP OF FIREPLACE
OPENING
6 IN. MIN.
12 IN.
MIN.
8 IN. MIN.
FINISH WALL
COMBUSTIBLE
3”
4-3/4”
6”
7-1/2”
9”
10-1/2”
12”
Height 
above 
opening
in.
6
7
8
9
10
11
12
mm 152
178
203
228
254
279
205
Horizontal 
Mantel 
distance
in.
3
4-3/4
6
7-1/2
9
10-1/2
12
mm
76
121
152
191
228
267
305
E. Hearth Extension
The base of the fi replace may sit on a 
combustible surface.  The area in front of 
the fi replace must be protected by a non-
combustible hearth extension, unless the 
fi replace is raised a minimum of 3 inches 
above the combustible fl oor or hearth. 
 
See fi gures 3.5 and 3.6.
12 in.
1 in. Max.
MARBLE, GRANITE, TILE OR
OTHER NON-COMBUSTIBLE
HEARTH EXTENSION
WOOD OR OTHER COMBUSTIBLE
FLOOR OR PLATFORM
BOTTOM OF FIREPLACE
FRONT EDGE
OF ASH LIP
FRONT EDGE
OF ASH LIP
COMBUSTIBLES UP TO
1 INCH THICK ALLOWED
UNDER THE OPENING
4 INCH
BOTTOM
OF FIREPLACE
1 INCH
(BUILT INTO UNIT)
3 INCH MIN.
WOOD OR OTHER
COMBUSTIBLE
FLOOR OR PLATFORM
MAY BE
COMBUSTIBLE
MATERIAL
Figure 3.5  Fireplace sitting on combustible surface.
Figure 3.6  Fireplace raised a minimum of 3 inches away from combustible surface.