September 1, 2008
Quadra-Fire · Garnet-T · 7016-127F
Female Locking Lugs
Male Locking Lugs
Step 1. 
Determine the desired location of the appliance. Check to 
ensure that wall studs or roof rafters are not in the way when 
the venting system is attached. If this is the case, you may 
want to adjust the location of the appliance.
F.  Horizontal Termination
Figure 5.4
Figure 5.3   
Rear Installations for Use with 
Rear Vent Kit
Type B - 
Up & Out Installations for Top 
Vent Configurations
Type A - 
Type C - 45° Elbow in Corner Installation
90º ELBOW
PIPE LENGTH 
PIPE LENGTH 
WALL THIMBLE  
center line 
WALL THIMBLE COVER 
 
TERMINATION CAP
CENTER LINE 
W AL L  THIMBL E 
W AL L  THIMBLE COVER 
17-3/4 in. 
(451mm) 
TERMINATION CAP
45° Elbow
2 in. (51mm) Clearance from stove 
corner to combustible wall.
2 in. (51mm) 
Clearance from stove 
corner to combustible 
wall 
Wall Thimble 
Step 1. 
Determine the desired location of the appliance. Check to 
ensure that wall studs or roof rafters are not in the way when 
the venting system is attached. If this is the case, you may 
want to adjust the location of the appliance.
Step 2.  
Direct vent pipe is designed with a locking connection. To 
connect the venting system to the appliance flue outlet, a 
twist-lock adapter is built into the appliance at the factory.  
Wall thickness may vary.  Remember to include wall 
thickness in minimum clearances when figuring venting 
lengths for your installation needs.
Note:  Female ends of direct vent pipe/elbows are 
designed to slide straight onto the male ends of adjacent 
pipes by orienting the  pipe indentations so they match and 
slide into the entry slots on the male ends, see Figure 5.4.  
Push the pipe sections completely together, then twist-lock 
one section clockwise approximately one-quarter turn, until 
the two sections are fully locked. The female locking lugs 
may not be visible from the outside. They may be located by 
examining the inside of the female ends.
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
•  Ensure vent components are locked together correctly.
•  Pipe may separate if not properly joined.