Hearth & Home Technologies GARNET-D-MBK User Manual

Page of 56
Page  36
September 1, 2008
Quadra-Fire · Garnet-T · 7016-127F
I.    Ignition  Module  Access  and  Battery                                                                                           
    Replacement
Figure 8.16
   The ignition module is located under the appliance 
attached to the decorative cover. 
Lift off the appliance top and place it on a flat surface, with 
the porcelain side up to prevent damage.  
Remove the appliance front by sliding it upwards in the 
grooves, being careful not to chip the porcelain. Lay the 
appliance front face up on a flat surface.
With the cast iron front of the appliance removed, remove the 
decorative cover located under the appliance.  To remove the 
cover, remove the two screws on the front of the appliance 
that hold the cover in place. Pull the cover forward, down 
and out. The module will then be accessible for service or 
battery replacement.
The single "AA" 1.5V battery that powers the ignitor is 
located in the module. To replace the battery, open the 
battery compartment and remove the old battery.  Replace 
the battery making sure the polarity is correct.
To CLOSE the intake damper, pull the wingnut forward toward 
the front of the appliance.. 
To  OPEN  the damper, push the wingnut back. Adust the 
damper in 1/4 in. increments until the desired flame is 
achieved. After adjustment, tighten the nut.
Figure 8.17
   
Loosen the wingnut that secures the damper. The 
wingnut is located on the underside of the appliance, to the 
right of the pilot assembly. 
Figure 8.18
   The shutter is located on the underside of the 
appliance, on the right side.  To adjust the shutter, loosen 
the wingnut.. Retighten the wingnut after adjustment.
Moving the shutter bolt to the right closes the shutter. Moving 
the shutter bolt to the left, will open the shutter. Opening the 
shutter causes flames to become shorter and blue. Closing 
the shutter creates taller orange/yellow flames. 
NOTE:  Do not close so much as to cause a sooty flame. 
Improper adjustment can cause sooting in the firebox and/
or on the outside of a house with a horizontal termination.
After adjustment, tighten nut to lock in place.
K.  Shutter Adjustment
OPEN
CLOSE
The intake damper can be used with or without the flue restric-
tor to adjust the air flow. Opening the damper makes the 
flames shorter and more active. Closing the damper makes 
the flames taller and less active.
J.  Intake Damper Operation
OPEN
CLOSE