Hearth & Home Technologies PIER-HVB-CE User Manual
Heat & Glo • PIER/ST/L&RCOR-HVB-CE • 2068-900 Rev. H • 6/07
32
Step 4. Positioning, Leveling, and Securing
the Fireplace
the Fireplace
• Place the fireplace into position.
• Level the fireplace from side to side and from front to
back.
• Shim the fireplace with non-combustible material, such
as sheet metal, as necessary.
• Secure the fireplace to the framing by nailing or screwing.
• Holes are provided in the base pan for securing the unit
to the floor.
!
The diagram below shows how to properly position, level,
and secure the fireplace.
and secure the fireplace.
Figure 27. Proper Positioning, Leveling, and
Securing of a Fireplace
Securing of a Fireplace
Step 5. The Gas Control System
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
SOLID FUEL.
Figure 28. Gas Control System
Standing
Pilot
!
WARNING: 230 VAC MUST NEVER BE
CONNECTED TO A CONTROL VALVE IN A
CONNECTED TO A CONTROL VALVE IN A
MILLIVOLT SYSTEM.
Standing Pilot Ignition System
This system includes millivolt control valve, Standing Pilot,
thermopile/thermocouple flame sensor, and piezo ignitor.
thermopile/thermocouple flame sensor, and piezo ignitor.
Flame Sensor Rod
NAILING
TABS
(BOTH
SIDES)
SIDES)