Upon completing the gas line connection, a small amount 
of air will be in the lines. When fi rst lighting the pilot light, 
it will take a few minutes for the lines to purge themselves 
of this air.  Once the purging is complete, the pilot and 
burner will light and operate as indicated in the instruc-
tion manual. Subsequent lighting of the appliance will not 
require such purging.
Operating Guidelines and Maintenance Instructions 
 
Fire Risk
Be sure fi replace screen or glass doors are in 
place when burning fi replace logs. Unless other 
provisions for combustion air are provided, the 
screen or doors shall have an opening for intro-
duction of combustion air. THIS GAS LOG SET 
IS NOT DESIGNED TO OPERATE WITH AIR 
TIGHT GLASS DOORS. Adequate combustion 
and cooling air must be provided or the unit will 
not function properly.
WARNING
Fire Risk
Explosion Risk
WARNING:  To avoid possible injury, fi re  and 
explosion, please read and follow these pre-
cautions and all instructions on this appliance 
before lighting the pilot.  This appliance uses 
L.P. (Propane) gas which is heavier than air and 
will remain at fl oor level if there is a leak. Before 
lighting, smell at fl oor level and/or use other 
means (such as using a commercially-available, 
non-corrosive leak check solution on all piping 
and connections, using a gas detector, etc.) to 
check for gas leaks. NOTE:  L.P. (Propane) gas 
can become odorless and CANNOT always be 
detected by smell.
 
WARNING
B. Maintenance
Periodically remove the logs and examine the burner.  If 
dirty, clean with a soft brush.  Also examine the area around 
the burner air shutter and the pilot. Any dirt or lint in this 
area should be removed. This will ensure long life and 
trouble-free operation. 
The appliance and venting system should be inspected 
before initial use and inspected and cleaned at least an-
nually by a qualifi ed fi eld service person.
A. Before Lighting Appliance
Before lighting this appliance determine if it has a Standing 
Pilot or Intellifi re ignition system by viewing the wiring 
system and gas valve. If this appliance has a red or black 
ignitor button (see Figure 3 and Figure 4) this appliance 
has a Standing Pilot ignition system. If there is no red or 
black ignitor button, this appliance has an Intellifi re ignition 
system.
Before operating this appliance have a qualifi ed tech-
nician:
•  Remove all shipping materials.
•  Review proper placement of logs, rockwool, lava rock, 
and vermiculite.
•  Check the wiring.
•  Ensure that there are no gas leaks.
WARNING
This appliance has been supplied with an integral barrier 
to prevent direct contact with the fi xed glass panel. Do 
NOT operate the appliance with the barrier removed. 
Contact your dealer or Hearth & Home Technologies if the 
barrier is not present or help is needed to properly install one.
HOT SURFACES
Glass and other surfaces are hot during 
operation AND cool down.
Hot glass will cause burns.
•  Do not touch glass until it is cooled
•  NEVER allow children to touch glass
• Keep children away
•  CAREFULLY SUPERVISE children in same room as 
fi replace.
•  Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other 
fl ammable materials.
•  Keep clothing, furniture, draperies and other fl ammable 
materials away.
Improper installation, adjustment, alteration, service or 
maintenance can cause injury or property damage. Refer to 
the owner’s information manual provided with this appliance. 
For assistance or additional information consult a qualifi ed 
installer, service agency or the gas supplier.
Do NOT use this appliance if any part has been under water.  
Immediately call a qualifi ed service technician to inspect the 
appliance and to replace any part of the control system and 
any gas control which has been under water.
WARNING
WARNING