Step 1. 
Determine the desired location of the appliance. Check to 
ensure that wall studs or roof rafters are not in the way when 
the venting system is being planned. If this is the case, you 
may want to adjust the location of the appliance.
F.  Horizontal Termination
Figure 5.3   
Step 2.  
Direct vent pipe is designed with a locking connection. To 
connect the venting system to the appliance flue outlet, a 
twist-lock adapter is built into the appliance at the factory.  
Wall thickness may vary.  Remember to include wall thickness 
in minimum clearances when figuring venting lengths for 
your installation needs.
Note:  Female ends of direct vent pipe/elbows are designed 
to slide straight onto the male ends of adjacent pipes by 
orienting the  pipe indentations so they match and slide into 
the  entry slots on the male ends, see
 Figure 5.4.  Push 
the pipe sections completely together, then twist-lock one 
section clockwise approximately one-quarter turn, until the 
two sections are fully locked. The female locking lugs may 
not be visible from the outside. They may be located by 
examining the inside of the female ends.
Type A - Up & Out Installation
Type C - 45° Elbow in Corner Installation
Type B -  Straight Out Installation
45° Elbow
3/8 in. (10mm) Clearance from 
stove corner to combustible wall.
3/8 in. (10mm) 
Clearance from 
stove corner to 
combustible wall 
(for valve access 
on side).
Wall Thimble/Heat Shield 
WALL THIMBLE/  
HEAT SHIELD 
 
WALL THIMBLE COVER 
 
PIPE LENGTH 
 
PIPE LENGTH 
 
TERMINATION CAP
CENTER LINE 
90° ELBOW 
CENTER 
LINE
WALL THIMBLE COVER
PIPE LENGTH
SNORKEL KIT
WALL STRAP 14 in. (356mm) Wide
WALL THIMBLE / HEAT SHIELD
15-5/8 in. 
(397mm)
21 in. 
(533mm)
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
•  Ensure vent components are locked together correctly.
•  Pipe may separate if not properly joined. 
Female Locking Lugs
Male Locking Lugs
Figure 5.4
Fire Risk.
Explosion Risk.
Combustion Fume Risk.
Use vent run supports per installation instructions.
Connect vent sections per installation instructions.
•  Maintain all clearances to combustibles.
•  Do NOT allow vent to sag below connection 
point to appliance.
 •  Maintain specifi ed slope (if required).
WARNING
Improper support may allow vent to sag or separate.