Hearth & Home Technologies TIARA II-B User Manual

Page of 60
August 1, 2008
Page  29
Heat & Glo · Tiara I B & Tiara II B · 7010-149M
Figure 7.1
Shock hazard.
•  Replace damaged wire with type 105
O
 C 
rated wire.
•  Wire must have high temperature insulation.
CAUTION
Figure 7.2
D.  Ignition Module Access and Battery  
 
     Replacement
CAUTION
Label all wires prior to disconnection when servicing controls. 
Wiring errors can cause improper and dangerous operation. 
Verify proper operation after servicing.
The Ignition Module (automatic-ignitor) is located on the 
side of the appliance. This module was incorporated into the 
design of the Tiara I-B & II-B to facilitate "one hand" lighting 
of the appliance.  When the gas control knob is turned to 
the "Pilot" position, and depressed, the ignitor should begin 
sparking immediately. If the ignitor does not begin sparking 
immediately, then it is in need of service. 
The ignitor is located on a plate attached to the side of the 
appliance using two #8 Phillips head screws. To access the 
ignitor, remove the two screws securing the plate to the side 
of the appliance and slide the plate out.  
The single "AA" 1.5 V battery that powers the ignitor is 
located in the module. To replace the battery, open the 
battery compartment and remove old battery.  Replace the 
battery.  Make sure the polarity is correct.
O
FF
PIL
O T
ON
T
P
T
H
T
P
T
H
LO
H
I
E
A
P ILO
T
IGNITON MODULE
ON / OFF SWITCH
REMOTE SWITCH
BLACK
BLACK
VALVE
TH
TP
TPTH
PILOT ASSEMBLY
THERMOPILE
GAS PILOT
 IGNITER
THERMOC
OUPLE
CAUTION
Battery polarity must be correct or module damage will occur.