Hearth & Home Technologies TIARA II-B User Manual

Page of 60
Page  6
August 1, 2008
Heat & Glo · Tiara I B & Tiara II B · 7010-149M
2
Getting Started
Check building codes prior to installation.
•  Installation MUST comply with local, regional, state 
and national codes and regulations.
•  Consult local building, fi re offi cials or authorities having 
jurisdiction about restrictions, installation inspection, 
and permits.
CAUTION
A.  Design & Installation Considerations
B.  Tools and Supplies Needed
C. Inspect Appliance & Components
Heat & Glo direct vent gas appliances are designed to oper-
ate with all combustion air drawn from outside of the building 
and all exhaust gases expelled to the outside. No additional 
air source is required.
When planning an installation, it is necessary to determine 
the following information before installing.
Before beginning the installation be sure that the following 
tools and building supplies are available.  
Note:  Not all 
tools will apply to every installation.
Keep appliance dry. 
•  Mold or rust may cause odors.
•  Water may damage controls.
WARNING
•  Installation and use of any damaged appliance or vent 
system component.
• Modifi cation of the appliance or vent system.
•  Installation other than as instructed by Hearth & Home 
Technologies.
•  Improper positioning of the gas logs or the glass door.
•  Installation and/or use of any component part not approved 
by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
WARNING
Hearth & Home Technologies disclaims any 
responsibility for, and the 
warranty will be 
voided by, the following actions: 
Inspect appliance and components for 
damage. Damaged parts may impair safe 
operation.
WARNING
•  Do NOT install damaged components.
•  Do NOT install incomplete components.
•  Do NOT install substitute components.
Report damaged parts to dealer.
Where the appliance is to be installed.
The vent system confi guration to be used.
Gas supply piping.
Electrical wiring. 
Whether optional accessories - devices such as a 
blower, thermostat or remote control - are desired.
Carefully remove the appliance and components from   
the packaging.
Remove door and set aside on protective surface.
Remove log set and component pack from fi rebox.
Report to your dealer any parts damaged in shipment, 
particularly the condition of the glass.
Read all of the instructions before starting the 
installation.  Follow these instructions carefully 
during the installation to ensure safety and ben-
efi t.
Pliers
Gloves
Hammer
Framing Square
Phillips Screwdriver
Electric Drill / Bits
Flat Blade Screwdriver
Safety Glasses
Plumb Line
Voltmeter
Level
Wrenches
Manometer
Allen Wrench Set
Tape Measure
Ratchets / Sockets
1/2 - 3/4 in. Length, #6 or 
#8 Self-Drilling Screws
Non-corrosive Leak Check 
Solution or Combustible Gas 
Detector