NOTE: Have the gas supply line installed in accordance 
with local building codes, if any. If not, follow ANSI 
223.1. Installation should be done by a qualifi ed  installer 
approved and/or licensed as required by the locality. (In 
the Commonwealth of Massachusetts installation must be 
performed by a licensed plumber or gas fi tter.) 
A.  Fuel Conversions
Before making gas connections ensure that appliance be-
ing installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to 
meet the appliance and locality needs must be made by 
a qualifi ed technician using Hearth & Home Technologies 
specifi ed and approved parts.
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
•  Disconnect gas supply piping BEFORE 
pressure testing gas line at test pressures 
above 1/2 psig.
•  Close the manual shutoff valve BEFORE 
pressure testing gas line at test pressures equal 
to or less than 1/2 psig.
B.  Gas Pressures
Proper input pressures are required for optimum appliance 
performance. Gas line sizing requirements need to be 
made following NFPA51.
C.  Gas Connection
Verify inlet pressures.
•  High pressure may cause overfi re condition.
•  Low pressure may cause explosion.
•  Verify minimum pressures when other household 
gas appliances are operating.
Install regulator upstream of valve if line pressure 
is greater than 1/2 psig.
Gas Information
9
NOTE:  Gas line may be run from either side of the appliance 
provided the hole in the outer wrap does NOT exceed 2-1/2 
inches in diameter and does not penetrate the fi rebox.
NOTE:  A listed (and Commonwealth of Massachusetts 
approved) 1/2 inch (13 mm) T-handle manual shut-off valve 
and fl exible gas connector are connected to the 1/2 inch (13 
mm) control valve inlet. 
•  If substituting for these components, please consult 
local codes for compliance.
NOTE:  The gap between the supply piping and gas access 
hole may be caulked with high temperature caulk or stuffed 
with non-combustible, un-faced insulation to prevent cold 
air infi ltration.
Refer to Reference Section 16 for location of gas line 
access in appliance.
Gas Leak Risk
•  Support control when attaching pipe to 
prevent bending gas line.
Pressure requirements for appliance are shown in the 
table below. Minimum pressure must be met when other 
household gas appliances are operating.
Pressure
Natural Gas
Propane
Minimum Inlet 
Pressure
5.0 inches
w.c.
11.0 inches
w.c.
Maximum Inlet
Gas Pressure
14.0 inches
w.c.
14.0 inches
w.c.
Manifold Pressure
3.5 inches
w.c.
10.0 inches
w.c.