Hearth & Home Technologies SL-550TV-IPI-D User Manual

Page of 53
9
Heat & Glo  •  SL-550 / 750 / 950TV-D  •  2053-985 Rev. H  •  9/06
3
Framing and Clearances
NOTE:
 Illustrations refl ect typical installations and are FOR 
DESIGN PURPOSES ONLY.
  I
llustrations/diagrams are not drawn to scale.
•  Actual installation may vary due to individual design 
preference.
Fire Risk
Provide adequate clearance:
•  Around air openings
• To combustibles
•  For service access
Locate appliance away from traffi c areas.
A.  Selecting Appliance Location
When selecting a location for your appliance it is important to 
consider the required clearances to walls (see Figure 3.1).
Figure 3.1  Appliance Locations
Model
A
B
C
D
E
F
SL-550TV-D
Inches
41-1/2
37
58-3/4
16-1/4
1/2
Millimeters
1054
940
1492
413
13
SL-750TV-D
Inches
45
42
63-3/4
16-1/4
1/2
Millimeters
1143
1067
1619
413
13
SL-950TV-D
Inches
50
49
70-3/4
16-1/4
1/2
Millimeters
1270
1245
1792
413
13
A
A
B
E
B
ALCOVE
INSTALLATION
TOP VENT
TOP VENT
D
F
B
C
TOP VENT
NOTE:  For actual appliance dimensions refer to 
Section 16.
In addition to these framing dimensions, also reference the following sections:
•  Clearances and Mantel Projections (Sections 3.C and 3.D)
•  Vent Clearances and Framing (Section 6).
WARNING