Hearth & Home Technologies SL-350TRS-CE-D User Manual

Page of 44
Heat & Glo  •  SL-350TRS-CE-D  •  2033-900  Rev. N  •  10/07
34
WARNING: DO NOT CONNECT 230 VAC
TO THE WALL SWITCH OR THE
CONTROL VALVE WILL BE DESTROYED.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING ER-
RORS CAN CAUSE IMPROPER AND DANGER-
OUS OPERATION. VERIFY PROPER OPERA-
TION AFTER SERVICING.
!
OPTIONAL WALL SWITCH
THERMOSTAT OR REMOTE
REMOTE SWITCH
PIGTAIL
OFF
ON
ON/OFF
SWITCH
THERMOPILE
TP/TH
TP
TH
GAS VALVE
THERMOCOUPLE
!
Step 9
Finishing
The following diagram shows the minimum vertical
and corresponding maximum horizontal dimensions
of fireplace mantels or other combustible projections
above the top front edge of the fireplace. See Figures
2 , 3 and 4 for other fireplace clearances.
Only non-combustible
materials may be used
to cover the black
fireplace front.
Figure 42.
Minimum Vertical and Maximum
Horizontal Dimensions of Combustibles
above Fireplace
Figure 41. Standing Pilot Ignition Wiring Diagram
WARNING: WHEN FINISHING THE
FIREPLACE, NEVER OBSTRUCT OR
MODIFY THE AIR INLET/OUTLET
GRILLES IN ANY MANNER.