Heat & Glo  •  SL-550 / 750 / 950TV-D  •  2053-985 Rev. H  •  9/06
A.  Pipe Clearances to Combustibles
Vent  Clearances and Framing
6
Fire Risk.
Explosion Risk.
Maintain vent clearance to combustibles as 
specifi ed.
•  Do not pack air space with insulation or other 
materials.
•  National building codes recommend using attic 
shield to keep loose materials/insulation from 
contacting vent.
Failure to keep insulation or other materials away from vent 
pipe may cause fi re.
Figure 6.1  Pipe Clearances
CLEARANCE
AROUND VERTICAL
SECTIONS
TOP
CLEARANCE
SIDE AND
BOTTOM CLEARANCE
Follow vent pipe manufacturer’s instructions for all clear-
ances around pipe.
C.  Vertical Penetration Framing
Use B-vent manufacturer’s fi restops to provide adequate 
clearances.
Fire Hazard
Keep loose materials or blown insulation from 
touching the vent pipe.
• 
National building codes recommend using 
attic shield to keep loose materials/ blown 
insulation from contacting vent. 
• 
Hearth & Home Technologies requires the use 
of an attic shield.
WARNING
WARNING