Hearth & Home Technologies HUDBAY-FS User Manual

Page of 49
Page 2
Quadra-Fire  •  Hudson Bay  •  7003-121 Rev. i
      10/08
and Welcome to the Quadra-Fire Family
!
Hearth & Home Technologies welcomes you to our tradition 
of excellence!  In choosing a Quadra-Fire appliance, you 
have our assurance of commitment to quality, durability, and 
performance.
This commitment begins with our research of the market, 
including ‘Voice of the Customer’ contacts, ensuring we 
make products that will satisfy your needs. Our Research 
and Development facility then employs the world’s most 
advanced technology to achieve the optimum operation of 
our stoves, inserts and fi replaces.  And yet we are old-fash-
ioned when it comes to craftsmanship.  Each appliance is 
meticulously fabricated and gold and nickel surfaces are 
hand-fi nished for lasting beauty and enjoyment.  Our pledge 
to quality is completed as each model undergoes a quality 
control inspection.   From design, to fabrication, to shipping: 
Our guarantee of quality is more than a word, it’s Quadra-
Fire tradition, and we proudly back this tradition with a Lim-
ited Lifetime Warranty.  
We wish you and your family many years of enjoyment in the 
warmth and comfort of your hearth appliance.  Thank you for 
choosing Quadra-Fire.
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
LOCATION: ON BACK OF APPLIANCE
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ÉTIQUETTE 
Made in U.S.A. / Fait Aux États-Unis 
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, 
permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. 
This appliance is not convertible for use with other gases, unless a certified kit is used.
 / Cet appareil doit être utilisé 
seulement avec le gaz indiqué sur l’étiquette enregistré et peut être installé dans une maison mobile en place permanente 
dans les endroits permis par les codes locaux. Voyez le manuel du propriétaire pour des détails supplémentaires. Cet 
appareil ne doit pas être converti avec des autres gaz sans l’utilisation d’un ensemble de conversion certifié. 
MINIMUM CLEARANCES TO COMBUSTIBLES / ESPACE MINIMUM AUX COMBUSTIBLES 
Minimum clearances required from combustible construction for all appliance surfaces. /  
Espaces minimum exigés de la construction combustible aux surfaces de l’appareil. 
FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE Blower Electrical Rating / Évaluation du 
Ventilateur Électrique: 115 V., 1.5 Amps, 60 Hz, 150 Watts 
ELECTRICAL SUPPLY / FOURNITURE ÉLECTRIQUE: 120 Volts, 1.2 Amps, 60 Hz 
Thermal Efficiency up to / Efficacité Thermique Jusqu'à:     84.02% NG (blower on / avec ventilateur allumé) 
 
  85.71% LP (blower on / avec ventilateur allumé) 
P.4.1-02 Canada Minimum pipe (P.4.1-02 Le canada tuyau minimum)  64.03% NG / 65.43% LP 
APPROVED FOR CANADA AND USA TO: 
ANSI Z21.88-2002 / CSA 2.33-2002 Vented Gas Fireplace Heaters, and applicable sections of UL307b Gas Burning 
Heating Appliances for Manufactured Homes and Recreational Vehicles, CAN/CGA 2.17-M91 “Gas Fired Appliances 
for use at High Altitudes.” 
This appliance is manufactured for operation with Natural Gas. 
For conversion to propane use Manufacturer’s conversion kit and instructions supplied with the appliance. This 
appliance may be installed in a bedroom or bedsitting room; in Canada remote thermostat installation is required. 
APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS: 
ANSI Z21.88-2002 / CSA 2.33-2002 Fournaises au Gaz avec Ventilation, et les sections applicable de UL 307b Appareils 
de Chauffage Au Gaz pour les Maisons Mobiles et les Véhicules Motorisés, CAN/CGA 2.17-M91 “Gas Fired Appliances for 
use at High Altitudes”. 
Cet appareil est manufacturé pour l’opération avec le Gaz Naturel. 
Pour une conversion au gaz propane les pièces du Manufacturier Cet appareil peut être utilisé dans une chambre à coucher 
ou salle de séjour; au Canada, l’installation d’un thermostat à distance est exigée. 
CAUTION:
 
HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP CHILDREN, CLOTHING, FURNITURE, 
GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY.
 
ATTENTION:
 
CHAUD LORQU’IL EST EN OPÉRATION. NE TOUCHEZ PAS. DES BRÛLURES SÉVÈRES PEUVENT EN RÉSULTER. 
GARDEZ LES ENFANTS, LES VÊTEMENTS, LES MEUBLES, LA GAZOLINE ET LES AUTRES LIQUIDES DE VAPEUR INFLAMMABLE ÊLOIGNÉS. 
CAUTION:
 
DO NOT OPERATE THIS APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S) 
SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON. 
ATTENTION:
 
CET APPAREIL NE DOIT PAS ÊTRE OPÉRÉ SI LA VITRE EST BRISÉE, CRAQUÉE OU ENLEVÉE. LE REMPLACEMENT 
DU PANNEAU DOIT ÊTRE FAIT PAR UNE PERSONNE LICENSÉE ET QUALIFIÉE. 
Date of Manufacture / Date du Manufacturier 
2005 2006 2007 
Feb  Mar  Apr  May  Jun  Jul  Aug  Sep  Oct  Nov  Dec 
Jan 
 
7003-122 
 
HEARTH: A non-combustible hearth pad is not required. However, the floor beneath the stove must be stable, level, and 
strong enough to support the stove without a tipping hazard.
 / CHEMINÉE: Un coussinet non-combustible de cheminée 
n’est pas exigé. Cependant, le plancher en dessous du poêle doit être droit, à niveau et assez fort pour supporter le poêle 
sans le hasard de basculer. 
This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts 
approved)
; if none, follow the National Fuel Gas Code, ANSI Z223.1 or Canadian Installation Codes,  
CAN/CGA-B149.  
NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or 
licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed 
plumber or gas fitter.) 
Cet appareil doit être installé selon les codes locaux, s'il-y-a-lieu  (et approuvé par dans la République de Massachusetts); 
sinon suivez les codes THE NATIONAL FUEL GAZ ANSI Z223.1; ou les codes Canadian Installation Codes  
CAN/CGA-B149.
  
REMARQUE: Le conduit gaz doit être installé conformément aux codes de construction locaux. L'installation doit être effectuée 
par un technicien qualifeé et/ou muni d'une licence de manière à respecter les règlements municipaux. (Dans la République 
de Massachusetts, l'installation doit être effectuée par un plombier ou un installateur d'appareils à gaz agrée.) 
Keep burner and control compartment clean. See installation and operating instructions accompanying this appliance. 
Gardez le brûleur et le compartiment de contrôle propres. Vérifiez les instructions d’installation et d’opération qui accompagnent 
cet appareil. 
This appliance equipped for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’ (0-1370m). 
In USA for Altitudes above 2000’, the vent configuration, orifice, or combination of both may need to be changed. 
See Owner’s Manual for information on making these changes. 
/ Cet appareil est équipé pour les altitudes de 0-2000’ 
(0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500’ (0-1370m). Pour les altitudes au dessus de 2000’ aux 
États-Unis, la configuration du ventilateur, son orifice ou les deux peuvent possiblement avoir à être changé. Voyez le 
manuel du propriétaire pour les informations sur ces changements. 
 
This appliance must be properly connected to a venting system in accordance with the manufacturer's installation 
instructions. 
/ Veuillez lire les instructions d'installation et d'opération qui accompagnent cet apareil 
Input Rate on “HI” (BTU/Hr) 
Puissance Évaluée à “HI” (BTU/Hr) 
  
Input Rate on “LO” (BTU/Hr) 
Puissance Évaluée à "LO" (BTU/Hr) 
Main Burner Orifice (DMS) 
Orifice du Brûleur Principal 
 
 
Minimum Inlet Pressure (Inches W.C.) 
Pression Minimum de la Valve (pouces W.C.) 
Maximum Inlet Pressure (Inches W.C.) 
Pression Maximum de la Valve (pouces W.C.) 
Manifold Pressure on “HI” (Inches W.C.) 
Pression du Collecteur d’ Échappement à “HI” (pouces W.C.) 
For use with Natural Gas 
Usage au Gaz Naturel 
0-2000’ 
42,000 
 
28,000 
 
.125” 
 
4.5“ 
 
7.0” 
 
3.5” 
 
For use with Propane 
Usage au Gaz Propane 
0-2000’ 
40,500 
 
31,000 
 
.076” 
 
11“ 
 
14” 
 
10” 
 
A. 
Top of stove to side wall 
 
B.       Side of stove to side wall 
 
C.       Back of stove to side wall 
 
D.       L/H & R/H corner to side wall 
 
E.      Min. alcove floor to ceiling height 
 
F.     
Maximum alcove depth 
 
G.     
Minimum alcove width 
 
H.      Top of stove to ceiling  
 
9" (228.6 mm) 
9 5/8” (244.5 mm)   
1" (25.4 mm) 
 
4” (101.6 mm) 
 
54” (1372 mm) 
 
36" (914.4 mm) 
 
46.5" (1181 mm)   
21” (533.4 mm) 
 
SAMPLE 
SA
MP
LE
 
Report No. / Rapport Numéro 
061-S-29b-5 
MODEL / MODÈLE 
HUDSON BAY 
  SERIAL  NO. 
 800 West Jefferson Street
 Lake City, MN 55041
www.quadrafire.com
002
FOURNAISE AU GAZ AVEC 
VENTILATION 
NE PAS UTILISER AVEC LE 
COMBUSTIBLE SOLIDE 
VENTED GAS FIREPLACE HEATER 
NOT FOR USE WITH SOLID FUEL  
Manufactured Date
Serial Number
Model Name
Test Lab & Report No.
Barcode