Hearth & Home Technologies 839-1390 User Manual

Page of 56
         September 1, 2008
Page  11
Quadra-Fire · Sapphire · 250-7233H
D. How to Use the Vent Graph
E. Venting Guidelines
NOTE: IF YOUR INSTALLATION FALLS WITHIN A 
SHADED AREA ON THE GRAPH, THE DAMPER MUST 
BE USED. 
NOTE: In the Commonwealth of Massachusetts, the word 
damper shall be replaced with the words flue restrictor.
1.  Measure the distance from the top of appliance to the 
center of the 90° elbow. On the graph below, draw a 
horizontal line from that measurement on the vertical 
axis across until it intersects with the slanted line.
2.  From the point of this intersection, draw a vertical line to 
the bottom of the graph.
3.  The point at which this line meets the bottom line of the 
graph is the maximum length of the horizontal run. 
Example 1: 
If the vertical dimension from the top of the 
appliance to the center of the 90° elbow is 
7 ft. (2m), the horizontal run to the base of 
the temination cap must not exceed 13 ft.- 
2 in. (4m).
Example 2: 
If the vertical dimension from the top of the 
appliance is 21 ft. (6m), the horizontal run 
to the base of the termination cap must not 
exceed 7 ft.- 3in. (2m).
 
Example:  The use of 3 elbows would reduce the 
allowable horizontal run to 9 ft. (3 - 1 = 
2 elbows x 3 ft. = 6 ft.; 15 ft. max. - 6 ft.= 
9 ft. max.)
4.  Each 90° elbow is equivalent to 3 ft. (914mm) of vent 
pipe and each 45° elbow is equivalent to 1 ft. (305mm) 
of vent pipe, and must be subtracted from vent pipe 
run. A single vertical to horizontal 90° elbow is already 
calculated into the allowable 15 ft. (5m) run. Each 
additional 90° elbow reduces the maximum horizontal 
distance by 3 ft. (914mm).
Notes:  The maximum horizontal vent run is 15 ft. (5m) 
when the vertical vent rise is 10 ft. (3m).
 
The minimum horizontal vent run is 11 in. 
(279mm).
 
Minimum wall thickness is 4 in. (102mm).  Maximum 
wall thickness is 20 in. (508mm).
 
Horizontal sections require a 1/4 in. (6mm) rise for 
every 12 in. (305mm) of horizontal travel.
 
Exterior Vent Diameter = 6-5/8 in. (168mm); Inner 
Vent Diameter = 4 in. (101mm).
 
  Horizontal sections require noncombustible support 
every 3 ft. (914mm), e.g. plumbing tape.
EXCEPTION FOR REAR VENT KIT, HORIZONTAL 
INSTALLATION:
When installing the Sapphire in a rear vent configuration 
with no vertical rise: a snorkel kit must be used, and 
a derating orifice must be installed. The appropriate 
orifice is supplied with the rear vent kit.
For any vertical rise when rear venting, a minimum of 2 
ft. (610mm) vertical must be used prior to any horizontal 
run.
The maximum horizontal vent run is 2 ft. (610mm).
The maximum horizontal vent run with a 45° elbow is 14 
in. (356mm).
No external minimum rise is required.  The minimum 
horizontal vent run is 11 in. (279mm).
Figure 5.2
TOTAL HORIZONTAL RUN TO BASE OF THE 
TERMINATION CAP (EXCLUDING ELBOWS)
EX. 2
EX. 1
     11"   2'        4'         6'        8'       10'      12'      14'  15'
30'
28'
26'
24'
22'
20'
18'
16'
14'
12'
10'
 8'
 6'
 4'
 2'
 0'
(MAX)
(MIN)
TOP VENT GRAPH
REAR VENTING WITH VERTICAL RISE
    
  2'        4'         6'        8'       10'      
30'
28'
26'
24'
22'
20'
18'
16'
14'
12'
10'
 8'
 6'
 4'
 2'
 0'
(MAX)
(MIN)
VERTICAL DISTANCE 
FROM APPLIANCE 
TOP TO  90° ELBOW