September 1, 2008
Cumberland Gap Wood Stove
7006-188E 
The flue collar is reversible for either a top or rear venting 
installation.  The unit is shipped with the flue collar in the top 
vent position.
ACCESSORY HORIZONTAL FLUE SHIELD
Part HTSHLD-7006
IS REQUIRED ON ALL HORIZONTAL INSTALLATIONS.
Figure10C
CONVERTING COLLAR FOR REAR VENT INSTALLATION
1
.  Lift off cast top.  Remove 4 Phillips head screws from the 
heat shield and discard heat shield. See circled areas in 
Figure 10A.
2.  Remove 4 Phillips head screws from the rear shield, 2 
on each side, lift rear heat shield off and set aside. 
3.  Remove 1 bolt from each side of the flue collar using a 
Phillps head screwdriver and 7/16 wrench.  
4.  Turn flue collar to horizontal position.  Inspect sealant to 
ensure a leak free application.   Re-attach bolts.
5.  Re-attach the rear heat shield.
6.  Attach required accessory Horizontal Flue Shield with 
screws provided.  Figure 10B
7.  Place cast top on the unit. See Figure 10C for completed 
view.
REVERSIBLE FLUE COLLAR
Completed View
Figure 10A
Discard heat 
shield
Remove 4 screws and set 
rear shield & screws aside
Remove bolts and 
rotate flue collar
Rear Heat 
Shield
Remove cast top
Figure 10B
Secure 
Horizontal Flue 
Heat Shield