Hearth & Home Technologies 5100I-NL-B User Manual

Page of 44
Page 5
5100-I  ACT WOOD INSERT
438-0380D
September 1, 2008
1.  Starting Fire:  Open (push in) both controls fully. After a
wood load has been burning for 5 to 15 minutes (longer
for very large pieces) close the Start-Up Air Control by 
pulling it out.
2.  High Burn Rate:  Leave the Primary Air Control fully open. 
It is important to do this when reloading the appliance.
Failure  to  do  this  could  result  in  excessive  emissions 
(opacity/smoke).
After a wood load has been burning for 5 to 15 minutes on 
High set the controls as follows for desired burn rate.
3.  Medium High Burn Rate
:
Start  with  the  Primary Air 
Control pushed in (open) and then pull out 1” to 2-1/2”
(5-6mm).  Start-Up Air is closed.
4.  Medium Low Burn Rate:
Start with
the
 Primary Air Control 
pushed in (open) and then pull out 3/4” - 1” (19-25mm).
Start-Up Air is closed.
5.  Low Burn Rate:
Gradually close down the Primary Air 
Control, making sure to maintain flames. (Start-Up Air is 
closed.)  It is very important to maintain flames during 
the first few hours of a low burn, to avoid excessive air 
pollution.
NOTE:  To establish your settings, always begin with the
Primary Air Control pushed all the way in the OPEN setting 
and then pull out the required distance for the appropriate 
burn rate.
*NOTE:  These are approximate settings, and will 
vary with type of wood or chimney draft. Due to 
altitude and other environmental circumstances, 
this  operational  information  is  a  guideline  only.  
Similar burn rates may be obtained using other 
settings unique to your situation.
BTU / Hr
Below 10,000
10,000 - 15,000
15,000 - 30,000
Maximum Heat
Start-Up Air Control
Closed after 5 to 15 minutes
Closed after 5 to 15 minutes
Closed after 5 to 15 minutes
Closed after 5 to 15 minutes
*Primary Control
Pull to Stop
3/4” - 1” open
1” - 2-1/2” open
Fully open
E.  Heat Output
G.  Building A Fire
Before lighting your first fire: 
1.  Confirm the baffle is correctly positioned.  It should butt 
up against the rear air channel.
 Figure 25.1. 
.  Follow instructions on 
page 29 for cleaning plated sur-
faces.
3.  Remove all labels from glass.
There are many ways to build a fire.  The basic principle 
is to light easily-ignitable tinder or paper, which ignites the
fast burning kindling, which in turn ignites the slow-burning 
firewood.  Here is one method that works well:
1.  Place several wads of crushed paper on the firebox floor.  
Heating the flue with slightly crumpled newspaper before 
adding kindling keeps smoke to a minimum.
.  Lay small dry sticks of kindling on top of the paper.
3.  Open Start-Up Air Control and Primary Air Control fully.
.  Make sure that no matches or other combustibles are in 
the immediate area of the appliance. Be sure the room
is adequately ventilated and the flue unobstructed.
5.  Light the paper in the appliance.  NEVER light or rekindle 
fire with kerosene, gasoline, or charcoal lighter fluid; the 
results can be fatal.
6.  Once  the  kindling  is  burning  quickly,  add  several  full-
length logs 3 to 4 inches (76 - 102mm) in diameter. Be
careful not to smother the fire.  Stack the pieces of wood 
carefully; near enough to keep each other hot, but far 
enough away from each other to allow adequate air flow 
between them.
7.  When ready to reload, add more logs. Large logs burn
slowly, holding a fire longer.  Small logs burn fast and 
hot, giving quick heat.
F.  Burn Rates
For maximum operating efficiency with the lowest emissions, 
follow these operating procedures:
1.   Regardless of desired heat output, burn the appliance
with both air controls wide open for the first 5 to 15 min-
utes.
.   Regulate burn rate (heat output) by using the Primary  Air 
Control (center of the grille).  The Start-Up Air Control is 
used for initial start-up and reloading only.
.  Heat output settings:  Follow burn rate settings below.
4.  Burn dry, well-seasoned wood.
CAUTION
•  Build fire on brick firebox floor.
•  Do NOT use grates, andirons or other methods to support
fuel.
Figure 25.1
-ANIFOLD
#ERAMIC
2EAR